DT4281,DT4282 DIGITAL MULTIMETER    Remote Operation Manual 

P2/14 

Contents

 

1.

 

Remote Interface Overview ............................................................ 3

 

2.

 

Interface Parameters ..................................................................... 3

 

3.

 

About Command ............................................................................. 4

 

3.1.

 

Terminator ...................................................................................................... 4

 

3.2.

 

Return result .................................................................................................. 4

 

3.3.

 

Data Types ...................................................................................................... 4

 

4.

 

Summary of Commands ................................................................. 5

 

5.

 

Detail of Commands ....................................................................... 6

 

5.1.

 

Description of Commands .............................................................................. 6

 

5.2.

 

Combination response string function and range ........................................ 11

 

5.3.

 

Index of threshold of continuity check ......................................................... 11

 

5.4.

 

Index of threshold of diode test .................................................................... 12

 

5.5.

 

Index of standard impedance of dBm .......................................................... 12

 

5.6.

 

Count value of abnormal data ..................................................................... 13

 

6.

 

Compatible command with earlier products ................................14

 

Please note .............................................................................................14

 

 

 

Содержание DT4281

Страница 1: ...DT4280 Series DIGITAL MULTIMETER Remote Operation Manual HIOKI E E CORPORATION Aug 2021 Revised edition 4...

Страница 2: ...lt 4 3 3 Data Types 4 4 Summary of Commands 5 5 Detail of Commands 6 5 1 Description of Commands 6 5 2 Combination response string function and range 11 5 3 Index of threshold of continuity check 11 5...

Страница 3: ...2 Interface Parameters In order to operate the meter via a host computer or terminal the parameters in interface within the DT4281 DT4282 have to match the parameters the serial interface provided by...

Страница 4: ...tes a query command the return of the result will be in the following format Result CR LF 3 3 Data Types Returned message is the ASCII string from the meter responding to a query Table 2 Data Type Exp...

Страница 5: ...value of the relative main CALC REL OFFS2 Query the offset value of the relative sub SYST APS 0 1 Set the APS SYST BEEP 0 1 Set the action of the beeper SYST BLIT 0 1 Set the backlight SYST BATT Query...

Страница 6: ...ple HIOKI DT4281 121107517 Ver 1 00 SYST RST Put the meter to reset Syntax SYST RST Response OK SYST LLO Put the meter into the local lockout state Syntax SYST LLO Response OK SYST GTL Put the meter i...

Страница 7: ...0 CALC REL OFFS CALC REL OFFS2 Query the offset value of the relative main or sub Syntax CALC REL OFFS CALC REL OFFS2 Response data 2 data offset value range Example 20 600m SYST APS Set the APS Synta...

Страница 8: ...TAT Response ABCDEFGHIJKLMNOPQRSTUVWX 24char A Recording 0 OFF or 1 MAX or 2 MIN B Relative value REL 0 OFF or 1 ON C Filter 0 OFF or 1 ON D Beep 0 OFF or 1 ON E APS 0 OFF or 1 ON F Battery level 0 3...

Страница 9: ...or 1 on Example SYST FILTER 1 Response OK or CMD ERR SYST PEAK Set the peak Syntax SYST PEAK data 1 data 0 off or 1 on Example SYST PEAK 1 Response OK or CMD ERR SYST SLOW Set the average Syntax SYST...

Страница 10: ...e SYST CONDUCT 1 Response OK or CMD ERR SYST DIODE Set the threshold of diode test Syntax SYST DIODE data 1 data Index of threshold 0 6 Example SYST DIODE 1 Response OK or CMD ERR SYST DBM Set the sta...

Страница 11: ...60 ACDCV 6 60 600 1000 SEPV 60m 600m 6 60 600 1000 CONT 600 DIODE 4 RES 60 600 6k 60k 600k 6M 60M 600M TEMP 800 CAP 1n 10n 100n 1u 10u 100u 1m 10m 100m CLAMP 10 20 50 100 200 500 1000 nS 600 DCuA 600...

Страница 12: ...est Table 7 Index Threshold 0 0 15V 1 0 5V 2 1 0V 3 1 5V 4 2 0V 5 2 5V 6 3 0V 5 5 Index of standard impedance of dBm Table 8 Index Standard Impedance Index Standard Impedance 0 4 10 150 1 8 11 200 2 1...

Страница 13: ...e of abnormal data Response of count value query return the values shown in Table 9 in the case of abnormal data Table 9 Type of abnormal value Count value Over Range value 1000000 Invalid data 200000...

Страница 14: ...nto the local lockout state when in remote control This means no local key operation at the front panel is allowed during remote control GTL Put the meter into the local state clearing the remote stat...