3
Options (sold separately)
For the clamp current measurement (Compatible only with the
DT4253, DT4255, and DT4256)
9010-50, 9018-50, 9132-50
*4
Clamp-on Probe
9704
Conversion Adapter
Clamp-on probe
Rated current
Diameter of the measurable conductor
9010-50, 9018-50
500 Arms
46 mm or less
9132-50
1000 Arms
55 mm or less, 80×20 mm bus-bar
Temperature measurement (Only the DT4253)
DT4910 Thermocouples (K) (p. 50)
• Temperature measuring junction: Exposed type (welding)
• Sensor length: Approx. 800 mm
• Operating temperature: -40°C to 260°C (temperature
measuring part), -15°C to 55°C (connector)
• Allowable tolerance: ±2.5°C
Carrying Case
The instrument, test leads, instruction manual, and others can be stored in the
case.
C0201 Carrying Case
(p. 34)
3853 Carrying Case
C0202 Carrying Case
1
Ind.
Appx.
7
6
5
4
3
2
www.
GlobalTestSupply
.com