8 2321-20 WAVEFORM MODULE
143
1
2
3
4
5
6
7
8
9
APPX
IDX
(c) Alarm setting/recording function
Start trigger, and power outage/restoration are identified as alarm,
and during the availability of recording function, are recorded as
flash memory.
Start trigger:
Pre-trigger/post-trigger
Pre-trigger length and post-trigger length can be set as long as the
data length is not exceeded.
*Pre-trigger can be set for all triggers but there are limitations for post-
trigger setting.
❖
"Trigger correspondence table"(P.143)
Trigger filter
A trigger can be activated when the trigger condition continues for a
certain period of sampling time. Trigger filter can be set within a sam-
pling area of 0 to 255.
Trigger output
When the start trigger is activated, TRIG. OUT terminal becomes ac-
tive (Open collector ON).
Trigger output time can be chosen from the following:
• Continuation of output (reset from PC application)
• Specified output time (1 to 255 s, reset from PC application)
• During waveform retrieval (from start trigger to stop trigger or maxi-
mum recordable length)
Trigger correspondence table
(
indicates that setting is possible)
* Stop trigger only available in OR setting
Stop trigger (end of waveform recording)
Trigger setting items
Analog
Logic
External
CH synchro-
nization
Trigger
filter
Post-
trigger
Level
Window
Pattern
S
tart
trigg
e
r (s
ta
rt of
wav
e
for
m
re
c
o
rdin
g)
Analog
Level
×
Window
×
Logic
Pattern
×
External
--
×
×
timer
--
×
×
×
×
×
×
×
software
--
×
×
×
×
×
×
×
CH synchro-
nization
--
×
×
×
×
×
×
Measured
value
Level
×
×
×
×
×
×
×
Window
×
×
×
×
×
×
×
All waveform data will be erased when setting is changed.
Identification
method
For the analog trigger and logic trigger, the instantaneous value of each
sampling is identified, while for the measured value trigger, the measured
value at each second is identified. In both cases, it is effective for the respec-
tive mode.
Recording
contents
Data
time, CH, trigger type (Type 1)
Waveform recording is carried out under the conditions pre-set (b).
Power outage
Identification method, a power outage/restoration is identified after power
has been restored.
Recording contents: One Data set contains time and outage/restoration.
Содержание 2300 Smart Site
Страница 1: ...SMART SITE Instruction Manual 2300 February 2011 Revised edition 5 2300A981 05 11 02H...
Страница 13: ...Contents XII...
Страница 21: ...8 Service...
Страница 87: ...74 4 2304 20 PULSE MODULE...
Страница 105: ...92 5 2304 21 PULSE MODULE...
Страница 145: ...132 8 2321 20 WAVEFORM MODULE 8 1 4 Dimension Diagrams 103 9 1 Unit mm 96 1 110 1 103 3 1 94 6 1 68 5 1 4 1...
Страница 207: ...194 10 2332 20 POWER METER MODULE 10 1 4 Dimension Diagrams 94 5 1 103 3 1 103 9 1 110 1 96 1 45 5 1 4 0 5 Unit mm...
Страница 253: ...240 12 2342 20 OUTPUT MODULE...
Страница 275: ...262 14 2351 AIR MODULE 2352 20 WIRE MODULE...
Страница 285: ...272 15 2353 20 LAN MODULE...
Страница 317: ...304 18 2362 20 DC POWER MODULE...
Страница 345: ...332 20 2392 01 02 MODULE BASE...
Страница 347: ...334 21 Maintenance and Service...
Страница 348: ......
Страница 349: ......
Страница 350: ......
Страница 351: ......
Страница 352: ......
Страница 353: ......
Страница 354: ......
Страница 355: ......
Страница 356: ......
Страница 357: ......
Страница 358: ......
Страница 359: ......
Страница 360: ......
Страница 361: ......
Страница 362: ......
Страница 363: ......
Страница 364: ......
Страница 365: ......
Страница 366: ......