126
7 2306-20 MULTIFUNCTION MODULE
Alarm judgment and recording function
7.6.3
General Specifications
Alarm judgment is made at every sampling, and the history will be recorded in flash memory if the measured
value recording function remains active.
Judgment method
Criterion threshold can be set to either Hi or Lo.
The instantaneous value at every sampling is judged
(effective in any measurement mode.).
Recorded data
One data set contains time, generation/reversion, CH and judgment threshold.
Clock accuracy
±100 ppm (Reference value at temperature from 0 to 50°C (32 to 122°F) with-
out the communications module)
Dimensions
Approx.45.5 W × 96 H × 94.5 D mm (1.79"W × 3.78"H × 3.72"D)
(excluding projections)
Mass
Approx.290 g (10.2 oz)
Backup
Recorded data (saved in flash memory)
Data loss for up to 2 minutes before and after a power outage may occur.
Communication
interface
CAN bus
Maximum rated
voltage to earth
33 Vrms, 70 VDC
Rated supply voltage
5 V ±0.3 VDC
Maximum rated power
2.5 W
Dielectric strength
350 V AC Between input and CAN bus
(50/60 Hz, Response current 5 mA, 6 sec)
200 V AC Between input and channels
(50/60 Hz, Response current 5 mA, 6 sec)
Operating environment
Indoors, altitude up to 2000 m (6562-ft.)
Operational ranges for
temperature and humidity
0 to 50°C (32 to 122°F), 80%RH or less (with no condensation)
Temperature and
humidity ranges for storage
-10 to 50°C (14 to 122°F), 80%RH or less (with no condensation)
Accessories
Terminal block (6 polarities, 4 polarities: 4 each)
Sticker for the terminal block
Standards applying
Safety EN61010, Pollution Degree 2
Measurement Category I (anticipated transient overvoltage 330 V)
EMC
EN61326 Class A
Содержание 2300 Smart Site
Страница 1: ...SMART SITE Instruction Manual 2300 February 2011 Revised edition 5 2300A981 05 11 02H...
Страница 13: ...Contents XII...
Страница 21: ...8 Service...
Страница 87: ...74 4 2304 20 PULSE MODULE...
Страница 105: ...92 5 2304 21 PULSE MODULE...
Страница 145: ...132 8 2321 20 WAVEFORM MODULE 8 1 4 Dimension Diagrams 103 9 1 Unit mm 96 1 110 1 103 3 1 94 6 1 68 5 1 4 1...
Страница 207: ...194 10 2332 20 POWER METER MODULE 10 1 4 Dimension Diagrams 94 5 1 103 3 1 103 9 1 110 1 96 1 45 5 1 4 0 5 Unit mm...
Страница 253: ...240 12 2342 20 OUTPUT MODULE...
Страница 275: ...262 14 2351 AIR MODULE 2352 20 WIRE MODULE...
Страница 285: ...272 15 2353 20 LAN MODULE...
Страница 317: ...304 18 2362 20 DC POWER MODULE...
Страница 345: ...332 20 2392 01 02 MODULE BASE...
Страница 347: ...334 21 Maintenance and Service...
Страница 348: ......
Страница 349: ......
Страница 350: ......
Страница 351: ......
Страница 352: ......
Страница 353: ......
Страница 354: ......
Страница 355: ......
Страница 356: ......
Страница 357: ......
Страница 358: ......
Страница 359: ......
Страница 360: ......
Страница 361: ......
Страница 362: ......
Страница 363: ......
Страница 364: ......
Страница 365: ......
Страница 366: ......