PCM412 - Manuale per l'utente
Installation
24
25
2.2.2
Controls of Stop and Opening
For the opening (Start 1 and 2) and Stop command using the illustrated connection. Can be
made with push buttons, electronic keys (type SK103), proximity key (type PX100)
using the output of a dialer (TDC26 type) or a combination of both command units in
parallel. To use the timer block should be set in Automatic Condominium: in this way keep pressed the
START1command leave the gate open.
2.2.3
Connections photocells with relais
The PCM412 can use photocells with self-diagnosis type FX30 \FX30D or traditional one with
output relay 'type FX40D or FX55D.
Selecting the switch 8 activates the traditional photocell.
You can not use both type of photocells.
Installer both TX on the same side (eg.left) of the gate and RX on the opposite side (eg. Right)
and setting different channel.
If the central unit is powered with solar panels they are restore only when the gate is activate.
M
Tim r
e *
N.A.
APRE
I
CH UDE
NC
NA
C
NA
COL100PX
A
B
C
A
B
C
MOTORIDUTTORE 2*
GEARED MOTOR 2
*
12V~ 700W max
M
A
K
To l
ta
e i g
Op n n
Partial
Opening
TDC28
PX100
STOP
BIRD
PXRE
COLPX
PXR
MONITOR
BATTERY
ON
OFF
+
RX
24V
NC
+
-
+
-
TX
+
-
TX
+
-
24V
24V
RX
FX40D / FX55D
FX40D / FX55D
LAMP24FG
2
3
4
5
24V
NC
+
-
MOTORIDUTTORE 1*
GEARED MOTOR 1
*
12V~ 700W max