Installation
20
21
1
Introduction
1.1
Description of central unit
1.1
The PCM412 is an automation central unit for hinged gates for one or two doors, powered by
batteries, capable of driving 12V geared-motors, with automatic recognition of limit-stop and
stop in case of obstacle.
On the central is integrated a decoder for Dual Channel TWIN remote control, with
teach the codes to control the total or partial opening (one door only) that uses a
BIRD receiver type and there are also two buttons for manual control of the central and
learning of remote control codes.
The operating modes are selectable with DIP switches and allow the condominium mode automatic;
s t e p b y s t e p w i t h a u t o m a t i c r e c l o s i n g a n d s t e p b y s t e p w i t h s t o p . O t h e r
functions available with the DIP switches are the closing wing time of the two doors closed, the activation
hammering to release solenoid lock,the selection for gate type with single or double doors and the
photocell type.
Two trimmers regulate the time of thrust before stopping the movement in case of obstacle and pause
in automatic mode 'before the closure gate
T h e b o a r d a l s o h a s L E D s t h a t i n d i c a t e i n p u t s t a t u s ( S TA R T 1 , S TA R T 2 ,
STOP photocell opening and closing), as well as' the charge battery, the recognition of
two ratiomotors, the reversing connection to the batteries and an error report.
Also is present in terminal board output for driving an alert in case of absence or
inefficiency of the batteries.
Technical Features
!
Power supply voltage: 230 Vac 50 Hz + / - 5%
!
Batteries: 2x 12 Ah 7-18 Vdc
!
Consumption only board: 7mAca @ 230VAC or 24VDC @ 18mA
!
Input 24VDC solar panel to recharge batteries
!
Services output: 400 mA continuous 24Vdc, 2Ah max
!
Output signal light: 24V DC 25W
!
Output for electric lock
!
15mA max open collector output, 45V to indicate the battery charge
!
Battery charging pulse is from the network control panel solar power for
adjust the pulse width and voltage monitoring to detect the charge.
!
Monitoring and reporting reverse polarity 'batteries
!
Management photocells traditional relay 'or pulsed with auto-diagnosis
!
Integrated remote control receiver and antenna interface BIRD
!
Pause time for closing: 1 to 65 seconds adjustable with trimmer
!
Gates operating on one or two doors
!
Commands for total opening (both doors) or partial (only door)
!
Wing time closing doors: 4 or 8 seconds
!
Function door hammering electric fence to electric lock
!
Fuse on the transformer primary: cylindrical 5x20 delayed 500mA/250V
!
Mains supply fuse F1: 5x20 cylindrical rapid 8A/250V
!
Fuse F2-voltage: cylindrical 5x20 Fast 8A/250V
!
Fuse F3 supply services: cylindrical 5x20 fast 3.15A/250V
!
Geared motors 12Vcc/50W
!
Toroidal transformer 80VA
2
Installation
2.1
Example of installation
BOX Box with central unit PCM412 and battery
FTC2 Receiving external photocell
FTC2 Transmitting external photocell
FTC1 Receiving internal photocell
FTC1 Transmitting internal photocell
SERR Electric Lock mounted on DOOR1
MOTOR2 Geared-motor 12V on DOOR2
MOTOR1 Geared-motor 12V on DOOR1
STOP/START Key Selector with a key SC1
LAMPG
Electronic Warning light LAMPG24FG
BIRD
Antenna with VHF received BIRD
7
2
3
8
9
6
1
4
5
10
11
1
4
2
5
3
7
8
9
6
10
11
11
11
PCM412 - User Manual