PCM412 - User Manual
Introduction
18
19
Important Safeguards
!
Please read this manual thoroughly before installation and keep it for future reference.
!
Installation, electrical connections and adjustements must comply with technical and safety standards in
force.(EN12453).
!
HILTRON Srl cannot be held responsible for failure to observe technical standards in the construction of gates, or for any
deformation of gates which may occur during use.
!
This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly set
forth will affect the reliability of the product and/or could be source of hazard.
!
HILTRON Srl cannot be held responsible for any damage caused by improper use or different from the use for wich the
autamtion system is destined to.
!
Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.
!
Before carrying out any operations, turn off the system’s main switch.
!
An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.
Alternativel, use a 6A thermomagnetic breaker with a multi-pole switching.
!
Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.
!
Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the Yellow/Green wire of
the operator.
!
The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried out
only by qualified personnel.
!
For maintenance operations, use only original spare parts produced by HILTRON Srl. Do not carry out any modifications
to automation components. Packaging materials (plastic, cardboard, etc.) are a potential hazard and must be kept out of
reach of children.
!
The installer must supply all informations regarding manual operation of the system in the event of an emergency and
provide the end-user with this manual attached to the product.
!
The automation is fitted with an anti-crush safety system that is a torque control device.
!
In any case, HILTRON Srl suggests the installation of others safety devices, in accordance with standards in force,
system operating logic and weight and dimension of the gate.
!
The safety devices (i.e.: photocells, pneumatic edges, etc...) protect areas wherethere is a mechanical movement hazard
(i.e.: crushing, entrapment and cutting).
!
Each installation must be fitted with at least one flashing light (i.e.: item LAMP12FG) or with at signalling plate (i.e.: item
TRG) fixed to the gate.
!
HILTRON Srl cannot be held responsible regarding safety and correct operation of the automation in the event that parts
other than original parts produced by HILTRON Srl.
Contents
Chapter 1
Introduction
20
1.1 Description of central unit ...............................................................................................20
1.2 Technical Features..........................................................................................................20
Capitolo 2
Installation
21
2.1 Example of in stallation...................................................................................................21
2.2 Connections....................................................................................................................22
2.2.1
Alimentation .......................................................................................................23
2.2.2
Controls of Stop and Opening............................................................................24
2.2.3
Connections photocells with relais.....................................................................25
2.3 Connections photocells with relais..................................................................................11
Capitolo 3
Programmation
26
3.1 Automatic limit stop.........................................................................................................26
3.2 Dip-Switch.......................................................................................................................26
3.2.1
Mode of functionnement ....................................................................................27
3.2.2
Closing wing timing ............................................................................................29
3.2.3
Door hummering ................................................................................................29
3.2.4
Warning light ......................................................................................................29
3.2.5
Double or single door.........................................................................................29
3.2.6
Type of photocells ..............................................................................................29
3.3 Programmation remote control receiver TWIN ...............................................................30
3.3.1
Visualization of the remote control code on PCM412 ........................................30
3.3.2
Auto learning of the remote control code ...........................................................30
3.3.3
Programmation of a new code in TWIN .............................................................31
3.3.4
Visualization of existing code in TWIN remote control .......................................31
3.3.5
Battery replacement...........................................................................................31
4
Maintenance ...................................................................................................................32
4.1 Gate
...........................................................................................................................32
4.2 Fuses
...........................................................................................................................32