Alarm Output Active Time
How long the alarm output will last after triggered.
4. Click OK.
5. Optional: Set the switch on the upper right corner to ON to trigger the alarm output.
Configure Parameters for Lane Controller
After adding the lane controller to the client, you can configure its parameters for passing through
the lane.
Before You Start
Add access control device to the client.
Steps
1. Click Access Control → Advanced Function → Device Parameter to enter Parameter Settings
page.
2. In the device list on the left, select a lane controller and you can edit the lane controller's
parameters on the right.
3. Edit the parameters.
Passing Mode
Select the controller which will control the barrier status of the device.
●
If you select According to Lane Controller's DIP Settings, the device will follow the lane
controller's DIP settings to control the barrier. The settings on the software will be invalid.
●
If you select According to Main Controller's Settings, the device will follow the settings of
the software to control the barrier. The DIP settings of the lane controller will be invalid.
Free Passing Authentication
If you enable this function, when both entrance and exit's barrier mode is Remain Open, the
pedestrians should authenticate each time passing through the lane. Or an alarm will be
triggered.
Opening/Closing Barrier Speed
Set the barrier's opening and closing speed. You can select from 1 to 10. The greater the
value, the faster the speed.
Note
The recommended value is 6.
Audible Prompt Duration
Set how long the audio will last, which is played when an alarm is triggered .
Note
0 refers to the alarm audio will be played until the alarm is ended.
DS-K3B961TX Series Swing Barrier User Manual
99
Содержание DS-K3B961TX Series
Страница 1: ...DS K3B961TX Series Swing Barrier User Manual ...
Страница 18: ... The dimension is as follows DS K3B961TX Series Swing Barrier User Manual 5 ...
Страница 30: ...Figure 4 6 Sub Access Control Board Terminal DS K3B961TX Series Swing Barrier User Manual 17 ...
Страница 40: ...Figure 4 17 Remaining Closed DS K3B961TX Series Swing Barrier User Manual 27 ...
Страница 126: ...UD27483B ...