Note
You can check Offline Authentication to enable the super
password authentication when the access control device
is disconnected with the client.
Local Authentication and Super Password
Authentication by the access control device and by the
super password.
4) Select the added person/card group in the left list below and
it will be added to the Selected list on the right as the
authentication group.
5) Click the added authentication group in the right list to set
authentication times in the Auth Times column.
Note
• The authentication times should be larger than 0 and
smaller than the added personnel quantity in the
personnel group.
• The maximum value of authentication times is 16.
6) Click Save.
Note
• For each access control point (door), up to four
authentication groups can be added.
• For the authentication group of which authentication type is
Local Authentication, up to 8 person/card groups can be
added to the authentication group.
• For the authentication group of which authentication type is
Local Authentication and Super Password or Local
Authentication and Remotely Open Door, up to 7 person/
card groups can be added to the authentication group.
7. Click Save.
7.5.4 Configure Custom Wiegand Rule
Based on the knowledge of uploading rule for the third party
Wiegand, you can set multiple customized Wiegand rules to
communicate between the device and the third party card
readers.
Before You Start
Wire the third party card readers to the device.
Steps
Note
• By default, the device disables the custom wiegand function. If
the device enables the custom Wiegand function, all wiegand
interfaces in the device will use the customized wiegand
protocol.
• Up to 5 custom Wiegands can be set.
• For details about the custom Wiegand, see Custom Wiegand
Rule Descriptions.
1. Click Access Control → Advanced Function → Custom
Wiegand to enter the Custom Wiegand page.
2. Select a custom Wiegand on the left.
77