5-i nch High Speed Dome User Ma nual
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
28
ALARM
ALARM RESUME ON
ALARM SEQUENCE 5
ALARM REST DELAY 5
ALARM SETTING
BACK EXIT
ALARM SETTING
ALARM NUM 1
PRIORITY HIGH
ALARM ACT NONE
AUX NONE
ALARM INPUT OPEN
BACK EXIT
Figure 3-25
Alarm Configuration Menu
2.
Choose the alarm number.
Steps:
(1)
Move the cursor to
ALARM NUM
and click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3)
Click
IRIS+
again to confirm and exit edit mode of this column.
Note:
You can configure up to 7 alarms.
3.
Configure the alarm input.
Steps:
(1)
Move the cursor to
ALARM INPUT a
nd click the
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to set the input status. You can configure it as
OPEN
(Normally open),
CLOSE
(Normally closed) or
OFF
(disable the alarm input).
(3)
Click
IRIS+
again to confirm.
Note:
If you set the status as
OPEN
, alarm will be triggered by high electricity level; if you set the
status as
CLOSE
, alarm will be triggered by low electricity level; if you set the status as
OFF
, it
will be triggered when this input channel is shut off.
4.
Configure the alarm linkage action.
You can specify the linked action when an alarm occurs. On the
ALARM ACT
submenu, you can
set the alarm action as preset 1-8, pattern 1-4, patrol 1-8, panning scan, tilting scan, random
scan, frame scan, panoramic scan, day mode, night mode or none. You can also set the alarm
output for the alarm. Please refer to
Section 3.5.3
Configuring Auxiliary Alarm Output
for
details.
5.
Configure alarm priority.
Enter the
PRIORITY
menu and set the alarm priority as
HIGH
,
MID
or
LOW
.
If multiple alarms with different priorities are triggered at the same time, the speed dome only
responds to the alarm with the highest priority; if multiple alarms with the same priority are
triggered at the same time, then the speed dome will respond to each alarm according to the
defined alarm sequence.
3.5.2
Configuring Alarm Parameters
Purpose: