5-i nch High Speed Dome User Ma nual
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
26
ZONES
ZONE NUM 1
[UNDEFINED ]
EDIT LABEL
EDIT ZONE
ZONE STATUS ON
SCAN STATUS ON
CLEAR ZONE
BACK EXIT
Figure 3-22
Zone Configuration
2.
Choose the zone number.
Move the cursor to
ZONE NUM
and click
IRIS+
button to enter. Click the up and down buttons to
choose the zone number to be configured.
Note:
You can configure up to 8 zones.
3.
Edit the label of the zone.
Please refer to
Step 3. Edit the label of the preset
in
Section 3.4.2.
4.
Configure the zone area.
Steps:
(1)
Move the cursor and click
IRIS+
button to enter
EDIT ZONE
submenu.
(2)
You can see
SET LEFT LIMIT
on the screen. Click the direction buttons to set the left limit
stop.
(3)
Follow the prompts on the screen to set the right limit, up limit and down limit.
(4)
Click
IRIS+
button to save the settings and exit.
5.
Set the zone status and scan status.
ZONE STATUS:
enable/disable the current status of the zone.
SCAN STATUS:
enable/disable the scanning in the zone.
Note:
ZONE STATUS
is not editable. After you edited the zone, it will switch to
ON
automatically;
if you delete the zone, the
ZONE STATUS
will switch to
OFF
.
6.
Clear the zone settings.
Move the cursor to
CLEAR ZONE
and click
IRIS+
to clear all the settings of the current zone.
3.4.7
Clearing PTZ Control Settings
Purpose:
You can clear all user-defined PTZ control settings, including presets, patrols, patterns, zones and
time tasks. You can also clear privacy masks on this menu.
Steps:
1.
Enter the
CLEAR SETTINGS
menu:
MAIN MENU > DOME SETTINGS > CLEAR SETTINGS