5-i nch High Speed Dome User Ma nual
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
8
1.
Select the protocol.
Choose the protocol on
PROTOCOL SET
submenu. You can configure it as
AUTO MATCH,
PELCO-P, PELCO-D, HIKVISION, KALATEL
or
VICON
. When you choose
AUTO MATCH
, it is
protocol self-adaptive.
2.
Set the protocol status.
Set the
PROTOCOL STATUS SET
as
ON
to enable the user-defined protocol.
3.
Enable the RS-485 configuration diagnosis.
You can set
485CHECK
SET
as
ON
or
AUTO
for automatic RS-485 configuration diagnosis. If the
configuration is incorrect, an alert will be received; if you set the value as
AUTO
, it will
automatically stop the diagnosis when no errors exist.
Note:
If the speed dome uses PELCO-P or PELCO-D protocol, you can set the
PELCO CHECKSUM
as
ON
.
0
º
angle (initial position) configuration
Purpose:
You can define the initial position of the speed dome on the
ZERO ANGLE
submenu.
Steps:
1.
Move the cursor to
ZERO ANGLE
using the direction buttons and click
IRIS+
to enter.
2.
Click the left/right/up/down direction buttons to adjust the monitor angle of the speed dome to
find the initial position.
3.
Click
IRIS+
button to confirm and exit.
Other system configurations
1.
System time configuration
Steps:
(1)
Move the cursor to
SYS TIME
using the direction buttons and click
IRIS+
to enter.
(2)
Click the left/right direction buttons to position the cursor on the specific item
(year/month/day or hour/minute/second) of which you want to change the value.
(3)
Click the up/down direction buttons to increase/decrease the value.
(4)
Click
IRIS+
button to confirm and exit.
Y - M - D 07 01 18
H - M - S 15 33 25
DONE: OPEN
QUIT: OPEN
Figure 3-4
Set the System Time
2.
Fan parameter configuration
You can set the
FAN CONTROL
as
TEMP
(controlled by the temperature)
, ON
or
OFF
.
3.
EIS (Electronic Image Stabilization) function configuration