Section 4 - Troubleshooting
Symptom
Problem
Solution
Rotor Does Not Spin
Drive clutch is not engaged.
Move the clutch engage pin
to the Engaged Position.
Ensure the drive pin is
locked in position.
Broken Drive Belt.
Replace the belt.
Foreign material lodged in
housing.
Remove foreign material to
allow rotor to spin freely.
Check condition of knives.
Replace knives as pairs and
also replace knife pair on
opposite side of rotor to
maintain rotational balance.
Rotor bearing has seized.
Check bearings or replace.
Rotor Stops Spinning
Drive clutch pin has moved
out and no longer is
engaged with the drive
plate.
Move the clutch engage pin
to the Engaged Position.
Ensure the drive pin is
locked in position.
Belt has come off the
sheave or tensioner.
Place the belt on the
sheaves and the tensioner.
Check the alignment of the
sheaves and tensioner.
Adjust if needed.
Broken belt.
Replace the belt.
Drive Belt Loose
Spring tension
Adjust the spring tensioner.
Belt has stretched.
Replace the belt.
Adjust the spring tensioner.