Section 4 - Troubleshooting
4.0
TROUBLESHOOTING
Operation
Symptom
Problem
Solution
Excessive Rotor Vibration
Broken knife.
Replace knives in pairs.
Also replace knife pair on
opposite side of the rotor to
maintain rotational balance.
Missing knives.
Replace knives in pairs.
Also replace knife pair on
opposite side of the rotor to
maintain rotational balance.
Foreign material lodged in
chopper housing.
Remove foreign material.
Check condition of knives.
Replace knives as pairs and
also replace knife pair on
opposite side of rotor to
maintain rotational balance.
Check for damage to the
rotor. Contact Highline for
proper repair procedure.
Failed rotor end bearing.
Check if rotor rotation feels
rough. Replace failed
bearing.
Check for rotor side play.
Replace failed bearing.
Visually inspect bearing.
Replace failed bearing.
Chopper Panel Does Not
Fully Lower For Bedding
Operation
Material buildup.
Remove material.
Rear door sitting on knife
Move the knife.