APPLIANCE OPERATION MANUAL
-18
FAULT FINDING / ABNORMAL OPERATION
FAULT
POSSIBLE SOLUTION(S)
BURNER LIGHTS, BUT GOES OUT WHEN CONTROL IS
RELEASED (Gas)
CONTROL KNOB IS TO BE PRESSED DOWN FIRMLY, AND
HELD FIRMLY, DURING IGNITION PROCEDURE FOR 5
SECONDS.
CONTROL KNOB IS BOTTOMING OUT ON THE CONTROL
PANEL AND NOT ENGAGING THE FLAME FAILURE DEVICE
– HOLE IN KNOB NEEDS PACKING.
IF THIS IS A FAULT PRESENT ON THE WOK BURNER,
REFER TO THE CORRECT ASSEMBLY INSTRUCTIONS.
UNIT OCCASIONALLY EMITS A SPARK EVEN WHEN NOT
BEING OPERATED (Gas)
THIS USUALLY MEANS SOME MOISTURE ON THE
SWITCHING MECHANISM DUE TO SPILLAGE OR STEAM.
IT SHOULD SELF RECTIFY
FLAME ON WOK BURNER PRESENT UNDER SKIRT AND
LARGE BILLOWING FLAME IN MIDDLE OF BURNER. (Gas)
WOK BURNER IS INCORRECTLY ASSEMBLED OR
FOOD HAS BLOCKED PORTS. REFER TO ASSEMBLY
INSTRUCTIONS. OR CLEAN. CONTINUED OPERATION
IN THIS CONDITION MAY CAUSE DAMAGE. RECTIFY
IMMEDIATELY
FAULT FINDING/ ABNORMAL
OPERATION
PLEASE READ AND KEEP FOR FUTURE REFERENCE