Error Codes
When you turn on the fixture, it will complete a start-up procedure. The display may show“Err channel is XX” if there are problems
with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 6 who has the testing sensor for positioning. For example, when the
display shows “Err channel is Color wheel”, it means there is some error in channel 1. If there are some errors on channel 1, channel
3, channel 7 at the same time, you may see the error message “Err channel is Pan movement”, “Err channel is Tilt movement”, “Err
channel is Dimmer” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain error message
after performing reset more than 2 times, only the channels which have errors can not work properly, others can work as usual.
Please contact support if detailed assistance is needed.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The PAN- movement is not
located in the default position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing circuit mal-
functions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The TILT- move-
ment is not located in the default position after the reset.
Gobo Wheel 1 Er
(Gobo Wheel 1- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor
failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Gobo Wheel 1 is not located in
the default position after the reset.
Gobo Rot. 1 Er
(Gobo Rot. 1- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed
or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Gobo Rot. 1 is not located in the default
position after the reset.
Gobo Wheel 2 Er
(Gobo Wheel 2- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor
failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Gobo Wheel 2 is not located in
the default position after the reset.
Focus Er
(Focus - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed or
magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Focus is not located in the default position
after the reset.
CMY Er
(CMY - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed or mag-
net missing) or the stepping-motor is defective (or its driving IC on the main PCB). The CMY is not located in the default position after
the reset.
42
Содержание SolaSpot Pro 1500
Страница 1: ...Professional Moving Head User Manual Version 1 0 0...
Страница 5: ...5...
Страница 6: ...6...
Страница 8: ...8...
Страница 12: ...12 This page intentionally left blank to ensure new chapters start on right odd number pages...
Страница 17: ...Dimensional Drawings Dims listed in MM 17...
Страница 23: ...23...