Iris Er
(Iris - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed or mag-
net missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Iris is not located in the default position after
the reset.
Zoom Er
(Zoom - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed or
magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Zoom is not located in the default position
after the reset.
Color Er
(Color - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction (sensor failed or mag-
net missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Color is not located in the default position after
the reset.