CHAPTER 3
Menu System
34
intellaspot
TM
XT-1 User Manual
Setup Motors
This option is used when calibrating flag motors in
Production Homing, see
Production Homing
on page 51.
To run the motor setup routine:
1. Navigate to and select the
Test
Options
Menu
,
(see
Test Options Menu
on page 32).
2. Using the left and right arrows on the
Center
button, scroll to the
Setup
Motors
option and press
the
Enter
button to select.
Use the up and down arrows on the
Center
button to
scroll to
On
and press the
Enter
button to select and start the motor setup routine.
Encoders
Encoders maintain the Pan and Tilt position of the
fixture, but may need to be disabled to perform certain
test and maintenance procedures like optimizing a new
lamp.
To disable encoders:
1. Navigate to and select the
Test
Options
Menu
,
(see
Test Options Menu
on page 32).
2. Using the left and right arrows on the
Center
button, scroll to the
Encoders
option and press the
Enter
button to select. The default option is
On
.
3. Use the up and down arrows on the
Center
button to scroll to
Off
and press the
Enter
button
to disable the pan and tilt encoders.
Code Menu
This option is for factory use only in debugging situations.
DMX
[ ]
Setup
Motors:
Off
DMX
[ ]
Encoders:
On
Содержание intellaspot XT-1
Страница 8: ...viii intellaspotTM XT 1 User Manual...
Страница 14: ...xiv intellaspotTM XT 1 User Manual...
Страница 20: ...CHAPTER 1 Product Overview 6 intellaspotTM XT 1 User Manual...
Страница 30: ...CHAPTER 2 Setup and Configuration 16 intellaspotTM XT 1 User Manual...
Страница 72: ...CHAPTER 4 Fixture Programming 58 intellaspotTM XT 1 User Manual...
Страница 98: ...Appendix B Important Safety Information 84 intellaspotTM XT 1 User Manual...