4.10
Batteries
4.10.1
Operating Principles
•
The battery must be charged before using it for the first time because it is
delivered with an energy content as low as possible
•
The permissible temperature range for charging is from 0 °C to
+40 °C/+32 °F to +104 °F. For optimal charging, we recommend charging
the batteries at a low ambient temperature of +10 °C to +20 °C/+50 °F to
+68 °F if possible
•
It is normal for the battery to become warm during charging. Using the
chargers recommended by Leica Geosystems, it is not possible to charge
the battery once the temperature is too high
•
For new batteries or batteries that have been stored for a long time
(> three months), it is effectual to make only one charge/discharge cycle
•
For Li-Ion batteries, a single discharging and charging cycle is sufficient.
We recommend carrying out the process when the battery capacity indic-
ated on the charger or on a Leica Geosystems product deviates signific-
antly from the actual battery capacity available
•
The batteries can be operated from
−
20 °C to +55 °C/
−
4 °F to +131 °F.
•
Low operating temperatures reduce the capacity that can be drawn; high
operating temperatures reduce the service life of the battery.
4.10.2
Battery for the TS Instrument
1
7
2
6
2
3
5
4
008697_001
1.
Face the instrument so that the vertical drive screw is on the left.
The battery compartment is below the vertical drive. Turn the knob
to the vertical position, opening the lid of the battery compartment.
2.
Pull out the battery housing.
3.
Pull the battery from the battery housing.
4.
A pictogram of the battery is displayed inside the battery housing.
This pictogram is a visual aid to assist in placing the battery cor-
rectly.
First-time use/
charging batteries
Operation/discharging
Change battery step-
by-step
50
Operation
Содержание Leica Nova MS60
Страница 1: ...Leica TS60 MS60 TM60 User Manual Version 4 0 English...
Страница 93: ......