Description
Value
Maximum average radiant power
0.95 mW
Pulse duration
<1 ns
Pulse repetition frequency (PRF)
320 MHz
Beam divergance
<1.5 mrad
CAUTION
Class 2 laser product
From a safety perspective, class 2 laser products are not inherently safe for
the eyes.
Precautions:
▶
Avoid staring into the beam or viewing it through optical instruments.
▶
Avoid pointing the beam at other people or at animals.
A TS60/MS60 instrument is shown.
8681_002
a
b
a
Laser beam
b
Exit for laser beam
1.7
Electromagnetic Compatibility (EMC)
The term Electromagnetic Compatibility is taken to mean the capability of the
product to function smoothly in an environment where electromagnetic radi-
ation and electrostatic discharges are present, and without causing electro-
magnetic disturbances to other equipment.
WARNING
Electromagnetic radiation
Electromagnetic radiation can cause disturbances in other equipment.
Precautions:
▶
Although the product meets the strict regulations and standards which
are in force in this respect, Leica Geosystems cannot completely
exclude the possibility that other equipment may be disturbed.
Labelling