23.04.2014
10 / 21
NOTE:
It is prohibited to cut off power if the unit is filled with water. This will deactivate tank protection and circulating pump safeguards.
Login is the first item in Menu (below, on the left side). Press OK. Access screen appears where password should be entered
(photo below, to the right). By default, for the user it has been set to 0000 (press OK 4 times). After the next 5 minutes from
return to the main screen the password will be saved and there is no need to enter it again throughout the controller. Fitter’s
password is provided in installation and service instructions in the controller map.
Operation parameters settings
After approval we may enter parameter settings (screen view below on the left side). Scrolling arrow down, we may also see
second part of the list (below, to the right).
Heat pump parameters
3 items will appear when we enter heat pump parameters (OK pushbutton). Press OK, the value in grey field will start to pulsate.
Then, set the required value using arrows and confirm with OK.
YES - heat pump will work until the required water
temperature in the tank is reached. If the heat pump is
set to YES, its operation may be stopped only by an
alarm or settings of other equipment priorities.
NO - heat pump will not switch off
It is possible to change heated water setting within 10 to
60°C.