24
en
3.
Performance test!
If compressed air is escaping anywhere
else, recheck the hose connections to make sure they are
pushed in all the way.
Add on ”hold-down clamp“
NOTE
Before fitting accessories, disconnect machine from
compressed-air supply and unplug from mains power!
1.
Undo bolts on the cylinder holders and attach to the left
and right of the foot plate.
2.
Screw cylinder holders back on again so that the cylinders
are prevented from moving in under the drilling unit
(with angled section of cylinder holder facing machine
centre).
3.
Cut out foil in the hole underneath the control console
and insert manually operated valve with ring.
4.
Connect the two unattached transparent hoses to the
pneumatic cylinders.
5.
Pull out the thin and thick red blanks. On pulling out the
blanks, press down ring on coupler.
6.
Now push the thin and the thick black hose (coming from
the hold-down clamp unit) into the unattached couplers.
7.
Screw the ”OR“ valve (the smaller valve with three
connections) onto the inside of the control console
(two holes positioned one above the other). The black
connection must be at the top, with the valve‘s smooth
surface facing the viewer.
8.
Finally, screw the pneumatically operated 3/2 way valve
(the larger valve with the four connections, including
sound absorber) into the side of the control console
(vacant hole). The black hose and the sound absorber
must be at the top, with the valve‘s smooth surface
resting against the control console.
9.
Performance test!
If compressed air is escaping
anywhere else, please recheck the hose connections to
make sure they are pushed in all the way. Also refer to
exploded drawing in Section 12.
Accessory fence extension
Scaled fence extension
Push half the bracket onto the fence extension and
half of it onto the fence, then fasten in place with screws
and clamping blocks.
Fig. 21: Scaled fence extension
Fig. 20: Swivel unit with sensor roller
2.
Check whether the sensor roller is pushed up when moving
down the swivel unit. If it isn‘t, loosen the allen screw and
adjust the sensor roller unit.
Connecting BlueMax Mini hose
”without foot pedal“
1.
Disconnect the electropneumatic switch (EPS) - in the
control console, black box in the power supply lead - from
the control console.
2.
From this, detach the only thin transparent hose, also from
the Y-piece at the other end.
3.
Now push the thin black hose (coming from the sensor roller
valve) all the way into the blue EPS.
4. Screw the EPS back onto the control console.
5.
Performance test! If compressed air is escaping anywhere
else, recheck the hose connections to make sure they are
pushed in all the way.
Connecting BlueMax Mini hose
”with foot pedal“
1.
Detach the only thin transparent hose (in the control console)
from the Y-piece and the single reducer.
2.
Now push the thin blue hose (coming from the sensor roller
valve) all the way into the open end of the T-piece.
Add on ”swivel unit with sensor roller“
NOTE
Before fitting accessories, disconnect machine from
compressed-air supply and unplug from mains power!
Position swivel unit against drilling unit block and attach on
both sides with threaded stud, spring washers and washers
as shown in the exploded diagram in Section 12. Screw an
M6 cheese head screw all the way on the right hand side of
the drilling unit block. Vertical positioning of the swivel unit
can be corrected at the threaded stud with locknut.
1.
Turning the M8 x 10 allen screw provided, screw down
the ”sensor roller valve unit“ on the right hand side of
the drilling unit block so as to leave it angled away at the
bottom and pointing to the left.
Operation
Содержание BlueMax Mini Type 3
Страница 1: ...en Operating manual BlueMax Mini Type 3...
Страница 7: ...7 en...
Страница 17: ...17 en...
Страница 29: ...29 en...
Страница 37: ...37 en Fig 42 Exploded drawing 5...