background image

1

oPeratinG anD installation 

instrUCtions

Danish DesiGn . Danish QUality . Danish ProDUCtion

www.heta.dk

en

sCan-line 1000 stove

eCoDesiGn reaDy

Содержание Scan-Line 1000

Страница 1: ...1 oPeratinG anD installation instrUCtions Danish DesiGn Danish QUality Danish ProDUCtion www heta dk en sCan line 1000 stove eCoDesiGn reaDy...

Страница 2: ...2...

Страница 3: ...demark of Heta A S 09 05 2022 0037 1505 Version 2 3 Printed in Denmark Subject to printing errors and changes operating instructions Contents Before installation 4 5 1 Operating instructions 6 1 1 Bef...

Страница 4: ...r dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects t...

Страница 5: ...261 C St v 3 Mg Nm3 OGC 32 Mg Nm3 Ydelse nominel last 4 5 kw Virkningsgrad nominel last 81 St v NS 3058 3059 samlet v gtet par kelemission 0 63 g kg Br ndsel Tr ovnen er egnet l intermiterrende drift...

Страница 6: ...and the chimney is hot after about 3 5 minutes closed door and regulate the air into operating position We re commend all of the first fuel is burned with the combustion air fully open in the operatin...

Страница 7: ...ty ash into a combustible container 1 7 reduced burning The stove is approved for intermittent use Never turn down the air down so much that there does not come any flames from the tree Wait to close...

Страница 8: ...flow is 5 6 g sec Corresponding to 17 m hr of combustion air by burning 2 2 kg of wood The chimney height and diameter as well as the temperature difference between the flue gas and outside temperatu...

Страница 9: ...ating oil forms 3 171 tons CO2 As wood is a CO2 neutral heat energy source you save the environment about 1 3 kg CO2 every time you have used 1 kg normal wood 1 11 operational problems The chimney mus...

Страница 10: ...n be easily and effectively removed by using proprietary stove glass cleaner 1 15 Cleaning the oven Remove and clean baking racks and rails The oven should be cleaned with mild oven cleaner See fig 1...

Страница 11: ...hecking switch gasket for ashpan C S VI C S Checking changing gasket for flue pipe C S VI C S Checking changing vermiculite C S VI C S Lubricate hinges L VI L Lubricate lock L VI L Lubricate Ash pan L...

Страница 12: ...12 1 1 1 1 2 3 4 4 1 2 3 3 4 4...

Страница 13: ...on Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer...

Страница 14: ...ping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in reverse order Starting with...

Страница 15: ...y is 5 years on this product covering manufactu rer s defects 1 year on paint adhesion defects from purchase date from Heta and a 3 months total warranty for seals vermiculite and glass from the date...

Страница 16: ...23 0228 Back stone bottom left 1 6 0023 0227 Back stone top right 1 7 0023 0226 Back stone bottom right 1 8 0023 0232 Side stone right 1 9 0030 0201 Grate 1 10 0030 0024 Casted bottom 1 11 1027 0526 D...

Страница 17: ...ass 1 4 0023 3008 Door gasket Length 2 1 m 1 5 1513 0124 Door latch 1 6 1513 0123 Door latch 1 7 0008 1002 Set fzb M6x6 2 8 1027 0528 Hinge 2 9 0008 9082 Hinge pin 6x35 2 10 1013 0432 Glass clips 6 11...

Страница 18: ...oor 1 2 0008 9082 Round head rivet steel 6x35 2 3 0008 1002 Set screw M6x6 2 4 0023 3013 Glass gasket 1 5 0021 0067 Glass 1 6 1013 0432 Glass clips 6 7 0008 026041 M4x6 With flat head 6 8 0050 0301 Ra...

Страница 19: ...nce requirements 20 2 2 Floor 20 2 3 Chimney connection 20 2 4 Combustion air and ventilation 21 2 5 Stovedrawings measurments 22 2 6 Diagram for connecting HAC 23 2 7 Connecting direct air below or b...

Страница 20: ...ront of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable natio...

Страница 21: ...air inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into t...

Страница 22: ...5 801 958 768 243 R 9 0 7 476 928 265 92 115 802 Scan Line 1000 B Soapstone Soapstone top Steel Scan Line 1000 S Scan Line 1000 S Soapstone Soapstone top Steel 1292 767 94 264 1268 476 R 9 0 7 246 115...

Страница 23: ...ir pipe using flexi pipe both from the floor or behind the stove Flexi pipe not included Reducer Nr 0050 0515 Air intake 125 Flexi pipe to the floor Flexi pipe back outlet Direct air supply The dimens...

Страница 24: ...A B D 150 300 A C B D Combustible material Non flammable substrate Non flammable substrate Furniture Stove Minimum dimensions in mm Distance to flamable materials A rear the stove B at the sides C ove...

Страница 25: ...25 2 9 Disassembling soapstone before installation Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 26: ...26 1 2 1 2 Scan Line 1000 Scan Line 1000 B 1 2 Scan Line 1000 S assembling the thermal stones...

Страница 27: ...27 2 2 1 1 1 2 Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 28: ...eel model with casted top 1 2 3 4 Only use cover plate with casted top At the rear of the 1000B and the 1000S are two options for rear outlet See page 21 On the 1000S model the stone must be cut when...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...ciency NCV as received Useful efficiency at nominal heat output th nom 85 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output elmax kW At minimum h...

Страница 32: ...32...