7
The nominal output of 7.7 kW is equivalent to
a firing interval of approx. 50 minutes at 40%
open combustion air and 1.8 kg of wood.
The door must be closed
during operation.
Ensure when refueling that the wood is not too
close, it will cause poorer combustion, less heat
out-put and lower efficiency.
The fuel load, must be maintained below the top
series of air holes and within the outer vent in
each side. Fig. 6
When refueling be careful to place
the fuel into the combustion cham-
ber gently, (use the provided glove).
By not doing so you risk cracking or
breaking the vermiculite.
If there is reduced draft in the chimney, we re-
commend opening a window at stoking. This will
give better ventilation to the room and more oxy-
gen for combustion.
1.6 emptying the ash
By using the shaker grate, it rotates back and
forth so the ash falls through the holes and into
the ashtray. It is advantageous to leave a layer
of ash in the bottom of the combustion cham-
ber on top of the grate as insulation.
Be careful when emptying the
ashes out. There can be hot
embers left for a long time.
Never empty ash into a combustible container.
1.7 reduced burning
The stove is, approved for intermittent use.
Never turn down the air down so much that there
does not come any flames from the tree. Wait to
close the air until the flames haveburnt out and
the tree is transformed into glowing charcoal.
If you are looking for less heat out-put, achieve
this by fueling with smaller volumes of wood and
a lower operating air. You may not completely
close the operating air during firing.
Be aware that the stove will naturally soot if the
operating air is too low. This is not good for the
environment. There is also a risk for the glass,
the chimney and other parts will become sooted.
By a combination of the above and possibly
burning damp wood. Can lead to high levels of
soot that it becomes sticky. Causing the sealing
of the door to tear off when opening the door
the next day.
Never use the stove if the
seals are loose.
1.8 explosion!!!
It is very important never to leave
The stove after start up or refueling,
before the fire is established.
(Typically
1/2 -1
minutes)
The ash pan must be secure and
must not be able to move after
being locked.
Do not fire in the oven if the ash pan is not
locked. The guarantee is void if it is not
complied with.
5
Maximum
wood filling
6
Vermiculite
(stone)
7
8
9
10
Содержание Scan-Line 1000
Страница 2: ...2...
Страница 12: ...12 1 1 1 1 2 3 4 4 1 2 3 3 4 4...
Страница 25: ...25 2 9 Disassembling soapstone before installation Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...
Страница 26: ...26 1 2 1 2 Scan Line 1000 Scan Line 1000 B 1 2 Scan Line 1000 S assembling the thermal stones...
Страница 27: ...27 2 2 1 1 1 2 Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...
Страница 29: ...29...
Страница 30: ...30...
Страница 32: ...32...