background image

Explosion hazard may be possible, if filled with 
too much wood on the stove and the air supply 
is to low. As large amounts of gas are being de-
veloped and this may cause a flue gas explosion.

Warning!

One  must  always  use  cation  around 
the stove seen, as it gets very warm 
during use. (In excess of 90° C). 

 

Children should avoid contact with the stove.
Setting  up  a  fence  if  you  have  small  children 
may  be  necessary.  Do  not  place  flammable 
objects  like  drying  racks,  furniture,  curtains 
too close to the stove.

1.9 Draft conditions     

 

         

      and the chimney

Poor draft will not allow the stove to burn, as it 
should. The glass can soot, requires cleaning of 
the chimney more often, smoke can escape out 
when the door is open and it gives poor fuel ef-
ficiency. Leading to unnecessary polluting of the 
environment.

Good  draft  will  allow  the  stove  to  achieve  op-
timal  combustion  and  the  highest  possible  ef-
ficiency. Heta wood stoves are constructed so 
that it itself provides an optimal blend of com-
bustion air. This provides a high efficiency/heat, 
clean glass and low environmental impact.

Minimum chimney draft: 10 pascal. 

It is the draft that the stove has been tested and 
approved on. The minimum draft is necessary to 
provide  clean  burning,  beautiful  flame  picture, 
as well as achieving the rated efficiency.

There is a risk of smoke escaping into the room 
if the door is opened during vigorous firing, or if 
there is a lack of air supply to the room, for ex. if 
an extraction fan is in use. 

204°C, relative to 20°C. 
Flue  gas  flow  is:

 

5,6  g/sec.  Corresponding  to 

17 m³ / hr of combustion air by burning 2.2 kg 
of wood. 

The  chimney  height  and  diameter,  as  well  as 
the temperature difference between the flue gas 
and outside temperature generates the chimney 
draft. Chimney insulation is therefore important 
as new efficient stoves create lower flue tempe-
ratures.  Wind  and  weather  conditions  also  in-
fluence  draft,  in  some  cases  it  may  be  disad-
vantageous  wind  direction,  combined  with  the 
position of the chimney can cause negative draft 

(it blows through the chimney), causing smoke 
escape from the stove.

Before  using  after  a  long  period  of  inactivity, 
check  that  the  chimney  is  free  for  any  blocka-
ges. (soot build-up, bird nests, leaves etc.).

reduced draft can occur when:

• The temperature difference is too small 

   between smoke gasses and outdoor 
   temperature, for eg. poorly insulated chimney

• To short of a chimney
• The outside temperature is high, and indoor    

   temperature is low for eg. in summer

• False air in the chimney
• Chimney is blocked
• Air tight house (lack of combustion air supply)
• Poorly placed chimney for the surroundings,   

   for ex. the ridge and trees may cause 
   turbulence

Good draft occurs when:

• Th

e difference in temperature in the chimney  

   (warmer) and outside temperature (colder) 

• It is clear weather
• The chimney has the right height min 4 meters

   above the stove, and clear of the roof ridge.

1.10 fuel

Your  new  stove  is  EN  approved  for  firing  with 
wood fuel. You must therefore only burn clean, 
dry  wood  in  your  stove.  Never  use  your  stove 
to  burn  driftwood,  as  this  may  contain  a  lot  of 
salt which can damage both the stove and the 
chimney. Similarly, you must not fire your stove
with refuse, painted wood, pressure-impregna-

combustion
air

Содержание Scan-Line 1000

Страница 1: ...1 oPeratinG anD installation instrUCtions Danish DesiGn Danish QUality Danish ProDUCtion www heta dk en sCan line 1000 stove eCoDesiGn reaDy...

Страница 2: ...2...

Страница 3: ...demark of Heta A S 09 05 2022 0037 1505 Version 2 3 Printed in Denmark Subject to printing errors and changes operating instructions Contents Before installation 4 5 1 Operating instructions 6 1 1 Bef...

Страница 4: ...r dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects t...

Страница 5: ...261 C St v 3 Mg Nm3 OGC 32 Mg Nm3 Ydelse nominel last 4 5 kw Virkningsgrad nominel last 81 St v NS 3058 3059 samlet v gtet par kelemission 0 63 g kg Br ndsel Tr ovnen er egnet l intermiterrende drift...

Страница 6: ...and the chimney is hot after about 3 5 minutes closed door and regulate the air into operating position We re commend all of the first fuel is burned with the combustion air fully open in the operatin...

Страница 7: ...ty ash into a combustible container 1 7 reduced burning The stove is approved for intermittent use Never turn down the air down so much that there does not come any flames from the tree Wait to close...

Страница 8: ...flow is 5 6 g sec Corresponding to 17 m hr of combustion air by burning 2 2 kg of wood The chimney height and diameter as well as the temperature difference between the flue gas and outside temperatu...

Страница 9: ...ating oil forms 3 171 tons CO2 As wood is a CO2 neutral heat energy source you save the environment about 1 3 kg CO2 every time you have used 1 kg normal wood 1 11 operational problems The chimney mus...

Страница 10: ...n be easily and effectively removed by using proprietary stove glass cleaner 1 15 Cleaning the oven Remove and clean baking racks and rails The oven should be cleaned with mild oven cleaner See fig 1...

Страница 11: ...hecking switch gasket for ashpan C S VI C S Checking changing gasket for flue pipe C S VI C S Checking changing vermiculite C S VI C S Lubricate hinges L VI L Lubricate lock L VI L Lubricate Ash pan L...

Страница 12: ...12 1 1 1 1 2 3 4 4 1 2 3 3 4 4...

Страница 13: ...on Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer...

Страница 14: ...ping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in reverse order Starting with...

Страница 15: ...y is 5 years on this product covering manufactu rer s defects 1 year on paint adhesion defects from purchase date from Heta and a 3 months total warranty for seals vermiculite and glass from the date...

Страница 16: ...23 0228 Back stone bottom left 1 6 0023 0227 Back stone top right 1 7 0023 0226 Back stone bottom right 1 8 0023 0232 Side stone right 1 9 0030 0201 Grate 1 10 0030 0024 Casted bottom 1 11 1027 0526 D...

Страница 17: ...ass 1 4 0023 3008 Door gasket Length 2 1 m 1 5 1513 0124 Door latch 1 6 1513 0123 Door latch 1 7 0008 1002 Set fzb M6x6 2 8 1027 0528 Hinge 2 9 0008 9082 Hinge pin 6x35 2 10 1013 0432 Glass clips 6 11...

Страница 18: ...oor 1 2 0008 9082 Round head rivet steel 6x35 2 3 0008 1002 Set screw M6x6 2 4 0023 3013 Glass gasket 1 5 0021 0067 Glass 1 6 1013 0432 Glass clips 6 7 0008 026041 M4x6 With flat head 6 8 0050 0301 Ra...

Страница 19: ...nce requirements 20 2 2 Floor 20 2 3 Chimney connection 20 2 4 Combustion air and ventilation 21 2 5 Stovedrawings measurments 22 2 6 Diagram for connecting HAC 23 2 7 Connecting direct air below or b...

Страница 20: ...ront of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable natio...

Страница 21: ...air inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into t...

Страница 22: ...5 801 958 768 243 R 9 0 7 476 928 265 92 115 802 Scan Line 1000 B Soapstone Soapstone top Steel Scan Line 1000 S Scan Line 1000 S Soapstone Soapstone top Steel 1292 767 94 264 1268 476 R 9 0 7 246 115...

Страница 23: ...ir pipe using flexi pipe both from the floor or behind the stove Flexi pipe not included Reducer Nr 0050 0515 Air intake 125 Flexi pipe to the floor Flexi pipe back outlet Direct air supply The dimens...

Страница 24: ...A B D 150 300 A C B D Combustible material Non flammable substrate Non flammable substrate Furniture Stove Minimum dimensions in mm Distance to flamable materials A rear the stove B at the sides C ove...

Страница 25: ...25 2 9 Disassembling soapstone before installation Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 26: ...26 1 2 1 2 Scan Line 1000 Scan Line 1000 B 1 2 Scan Line 1000 S assembling the thermal stones...

Страница 27: ...27 2 2 1 1 1 2 Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 28: ...eel model with casted top 1 2 3 4 Only use cover plate with casted top At the rear of the 1000B and the 1000S are two options for rear outlet See page 21 On the 1000S model the stone must be cut when...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...ciency NCV as received Useful efficiency at nominal heat output th nom 85 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output elmax kW At minimum h...