1.18 troubleshooting table - applies to all stove types

Fault

Cause

Troubleshooting

Solution

Lighting problems. When the 
stove is cold, smoke seeps 
into the room. Once the com-
bustion chamber has heated 
up, the stove burns well.

Inadequate chimney draft. 
The chimney only has 
sufficient draft when it is hot.

You can test using a lighter whether 
flame is drawn into the combustion 
chamber. 

Improve the chimney.

The stove burns poorly after 
the warm-up phase, and the 
glass slowly soots up.

Soot in the flue pipe.

Check the flue pipe regularly, as the 
problem arises slowly.

Clean regularly, and limit the use 
of horizontal flue pipes. Do not use 
firewood which generates large 
quantities of ash.

If the stove burns poorly
after start-up, and the
glass slowly soots up.

Inadequate chimney draft.

The fault usually already occurs during 
lighting. Measure the chimney draft.

Improve the chimney draft. 

Insufficient air supply.

Check the air supply.

Read the operating instructions and 
instruct all users.

Damp wood.

Use clean, dry wood with a maximum 
moisture content of 20%.

Firewood should ideally be dried for 
at least one year after splitting.

Firewood pieces too large.

Optimal size – see the section for 
firewood, max. diameter 10 cm.

Use smaller pieces of firewood.

Insufficient air supply to the 
room. Range hoods, airtight 
windows, etc.

Ensure there is sufficient fresh air 
supply, open a window, check the 
outdoor air supply.

Depending on the cause, windows 
must be opened or the outdoor air 
connection cleaned. 

Insufficient air supply to the 
room. Range hoods, airtight 
windows, etc

Ensure there is sufficient fresh air 
supply, open a window, check the 
outdoor air supply.

Depending on the cause, windows 
must be opened or the outdoor air 
connection cleaned.

The vermiculite in the com-
bustion chamber is becoming 
very worn.

Wood and flue gases wear 
down the vermiculite.

Investigate whether the wear is 
normal. 

Normal wear and minor cracks are of 
no significance. It should be replaced 
when the steel of the combustion 
chamber is visible.

Too rapid combustion.

Too much chimney draft.

To test, you can open the cleaning 
hatch, but remember to close it again.

Measure the chimney draft and install 
a damper in the flue pipe if necessary.

The door or ash pan/drawer 
seal is defective.

While cold, close a piece of paper in 
the door – the seal should hold the 
paper gently in place so it does not 
fall out by itself. Normal wear.

Replace the seal.

The vermiculite in the 
combustion chamber is 
cracked.

Shocks or impacts while 
adding firewood.

Normal wear

Cracks only have cosmetic signifi-
cance. Replace when the steel of the 
combustion chamber is visible.

Steel surfaces in the 
combustion chamber 
have oxidised.

The temperature in the 
combustion chamber is 
too high.

Unsuitable fuel is being used (such as 
coal). Check the quantity of firewood 
being used, read the operating in-
structions.

If there are clear cracks or weak-
nesses in the stove body, it must be 
replaced.

The stove whistles

Too much chimney draft

To test, you can open the cleaning 
hatch, but remember to close it again.

Install a damper.

The stove 'clunks'

Usually due to tension in the 
metal plates.

Generally only occurs while heating up 
and cooling down.

Adjust the metal plates.

The stove ticks

Normal expansion and 
contraction due to 
temperature changes.

A normal sound.

Ensure that the temperature in the 
combustion chamber is as constant 
as possible.

The stove creaks.

The temperature in the com-
bustion chamber is too high.

Use less firewood. Also check the seal 
in the ash pan/drawer.

See the operating instructions.

The stove smells. 
The surface is steaming.

The paint on the stove sur-
ace is not yet fully hardened.

See the operating instructions 
regarding the first firing.

Ensure there is sufficient ventilation.

Condensation in the 
combustionchamber.

Moisture in the vermiculite.

Check the condition of the vermiculite.

Evaporates by itself after the stove has 
been lit a few times.

Damp wood.

Measure the moisture content.

Use dry firewood.

Condensation from the flue 
pipe.

The pipe is too long or the 
chimney is too cold.

Check the flue pipe's length and heat 
loss.

Improve the flue pipe, insulate the 
chimney.

Damp wood

Measure the moisture content.

Use dry firewood.

Moving parts creak. 

Needs lubercation.

What part .

Lubercate with graphite spray.

Содержание Scan-Line 1000

Страница 1: ...1 oPeratinG anD installation instrUCtions Danish DesiGn Danish QUality Danish ProDUCtion www heta dk en sCan line 1000 stove eCoDesiGn reaDy...

Страница 2: ...2...

Страница 3: ...demark of Heta A S 09 05 2022 0037 1505 Version 2 3 Printed in Denmark Subject to printing errors and changes operating instructions Contents Before installation 4 5 1 Operating instructions 6 1 1 Bef...

Страница 4: ...r dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects t...

Страница 5: ...261 C St v 3 Mg Nm3 OGC 32 Mg Nm3 Ydelse nominel last 4 5 kw Virkningsgrad nominel last 81 St v NS 3058 3059 samlet v gtet par kelemission 0 63 g kg Br ndsel Tr ovnen er egnet l intermiterrende drift...

Страница 6: ...and the chimney is hot after about 3 5 minutes closed door and regulate the air into operating position We re commend all of the first fuel is burned with the combustion air fully open in the operatin...

Страница 7: ...ty ash into a combustible container 1 7 reduced burning The stove is approved for intermittent use Never turn down the air down so much that there does not come any flames from the tree Wait to close...

Страница 8: ...flow is 5 6 g sec Corresponding to 17 m hr of combustion air by burning 2 2 kg of wood The chimney height and diameter as well as the temperature difference between the flue gas and outside temperatu...

Страница 9: ...ating oil forms 3 171 tons CO2 As wood is a CO2 neutral heat energy source you save the environment about 1 3 kg CO2 every time you have used 1 kg normal wood 1 11 operational problems The chimney mus...

Страница 10: ...n be easily and effectively removed by using proprietary stove glass cleaner 1 15 Cleaning the oven Remove and clean baking racks and rails The oven should be cleaned with mild oven cleaner See fig 1...

Страница 11: ...hecking switch gasket for ashpan C S VI C S Checking changing gasket for flue pipe C S VI C S Checking changing vermiculite C S VI C S Lubricate hinges L VI L Lubricate lock L VI L Lubricate Ash pan L...

Страница 12: ...12 1 1 1 1 2 3 4 4 1 2 3 3 4 4...

Страница 13: ...on Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer...

Страница 14: ...ping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in reverse order Starting with...

Страница 15: ...y is 5 years on this product covering manufactu rer s defects 1 year on paint adhesion defects from purchase date from Heta and a 3 months total warranty for seals vermiculite and glass from the date...

Страница 16: ...23 0228 Back stone bottom left 1 6 0023 0227 Back stone top right 1 7 0023 0226 Back stone bottom right 1 8 0023 0232 Side stone right 1 9 0030 0201 Grate 1 10 0030 0024 Casted bottom 1 11 1027 0526 D...

Страница 17: ...ass 1 4 0023 3008 Door gasket Length 2 1 m 1 5 1513 0124 Door latch 1 6 1513 0123 Door latch 1 7 0008 1002 Set fzb M6x6 2 8 1027 0528 Hinge 2 9 0008 9082 Hinge pin 6x35 2 10 1013 0432 Glass clips 6 11...

Страница 18: ...oor 1 2 0008 9082 Round head rivet steel 6x35 2 3 0008 1002 Set screw M6x6 2 4 0023 3013 Glass gasket 1 5 0021 0067 Glass 1 6 1013 0432 Glass clips 6 7 0008 026041 M4x6 With flat head 6 8 0050 0301 Ra...

Страница 19: ...nce requirements 20 2 2 Floor 20 2 3 Chimney connection 20 2 4 Combustion air and ventilation 21 2 5 Stovedrawings measurments 22 2 6 Diagram for connecting HAC 23 2 7 Connecting direct air below or b...

Страница 20: ...ront of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable natio...

Страница 21: ...air inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into t...

Страница 22: ...5 801 958 768 243 R 9 0 7 476 928 265 92 115 802 Scan Line 1000 B Soapstone Soapstone top Steel Scan Line 1000 S Scan Line 1000 S Soapstone Soapstone top Steel 1292 767 94 264 1268 476 R 9 0 7 246 115...

Страница 23: ...ir pipe using flexi pipe both from the floor or behind the stove Flexi pipe not included Reducer Nr 0050 0515 Air intake 125 Flexi pipe to the floor Flexi pipe back outlet Direct air supply The dimens...

Страница 24: ...A B D 150 300 A C B D Combustible material Non flammable substrate Non flammable substrate Furniture Stove Minimum dimensions in mm Distance to flamable materials A rear the stove B at the sides C ove...

Страница 25: ...25 2 9 Disassembling soapstone before installation Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 26: ...26 1 2 1 2 Scan Line 1000 Scan Line 1000 B 1 2 Scan Line 1000 S assembling the thermal stones...

Страница 27: ...27 2 2 1 1 1 2 Scan Line 1000 Scan Line 1000 B Scan Line 1000 S...

Страница 28: ...eel model with casted top 1 2 3 4 Only use cover plate with casted top At the rear of the 1000B and the 1000S are two options for rear outlet See page 21 On the 1000S model the stone must be cut when...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...ciency NCV as received Useful efficiency at nominal heat output th nom 85 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output elmax kW At minimum h...

Страница 32: ...32...

Отзывы: