Installation Manual
Version 1.1
10
Part Number MAN-000014
Wiring the BinTrac Power Supply
28. The Power Supply (PS17) is intended for inside use. As the BinTrac Breeder Control is installed in an office
or building walkway, the Power Supply can be installed in the same area near an outlet.
29. Mount the Power Supply in a location that allows the 12VDC cable to be ran a short distance to the Breeder
Control unit.
30. Once the cable is routed from the Power Supply to the BinTrac Breeder Control and has been tied up out of
the way, cut off any excess cable and connect into Breeder Control unit as shown below.
Wiring the BinTrac Dual Breeder Control
31. Locate the terminal block in the BinTrac Dual Breeder Control
labeled
‘SUMMING BOX’ (see
Figure 10
).
32. Insert the wires into the terminal block where RED is 12V OUT (+), GREEN is COM IN (+), WHITE is COM IN
(-), and BLACK is 12V OUT (-).
33.
Connect the wires from the BinTrac power supply to the terminal block labeled ‘POWER INPUT’ (see
Figure
10
) where WHITE is 12V IN (+) and BLACK is 12V IN (-).
34. After wiring the Smart Summing Box to the BinTrac Dual Breeder Control Indicator, you will then wire the
Auger Relay to the BinTrac Dual Breeder Control Indicator as shown in the addendums (
pages 11 through
14
). A voltage suppressor is provided with the Relay Kit (KIT-000028) and is to be connected across the
Auger Relay coil. In addition, an auto/manual override switch is included in the kit and should be installed as
well.
Reference
Addendum C
for complete system wiring diagrams for each configuration.
Figure 10: Insert wires in appropriate terminal
block.