13
Switch (11):
To confirm the setting and save.
Switch (6):
In “Run: Manual” mode, press and hold for manual purging the adhesi
ve for Channel
A without displaying or changing parameters.
Switch (9):
In “Run: Manual” mode, press and hold for manual purging the adhesive for Channel
B without displaying or changing parameters.
LED Light (10):
Light to show when the adhesive is in low level.
5.2 XS1 Start Signal:
The system auto detects when the footswitch(s) is connected to the system.
Operate two channels from a single start signal (Timed mode only)
Only XS1 Channel A (Master) Footswitch connected:
The footswitch can control both output of Channel A and Channel B and start at the
same time.
Operate one channel from a single start signal (Timed/Continuous mode)
Only XS1 Channel B Footswitch connected (Timed mode):
The footswitch can only control the output of Channel B.
XS1 Channel A or XS1 Channel B Footswitch connected (Continuous mode)
The footswitch controls the output of selected Channel.
Operate two channels from two independent start signals (Timed/Continuous
mode)
Both XS1 Channel A (Master) and XS1 Channel B Footswitch connected:
The footswitch will control their own channel and can be started at different times.