8
1. Valve Pressure Relief
2. Reservoir/Lid Fitting
3. Display
4. Mode Switch
5. Right Arrow Switch
6. Manual Switch for Channel A
7. Set Switch
8. Up Arrow Switch
9. Manual Switch for Channel B
10. Low Level Error LED Light
11. Enter Switch
12. Air Pressure ON/OFF Switch
13. Main Power ON/OFF Switch
14. Tank Pressure Gauge
15. Tank Pressure Regulator
16. Channel A ON Output
17. Channel A OFF Output
18. Channel B ON Output
19. Channel B OFF Output
20. XS1 Channel A (Master)
21. XS1 Channel B
22. Air Pressure In
23. 24VDC Power In
24. Silencer
25. Low Level Sensor
26. Reservoir
3
Technical Data
Dimensions (L x H x W):
214x363x357 mm
Total weight: Kg (lbs.)
11 (24)
Power Supply:
110~240 VAC 50/60Hz
Internal control voltages:
24VDC
Power consumption:
Approx. 25 Watts
Pneumatic Supply:
Clean, dry air not to exceed 125psi (8.5bar). and
filtered with a maximum of 50 micron.
Operating Temperature:
+10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature:
-
10 °C to +60 °C (+14 °F to +140 °F)