EN-13
INITIAL SETUP MENU
Menu dedicated to the start up of the machine. Useful
in the initial installation phase.
To enter the Basic Setup :
•
Power off the generator.
•
Power on the generator by holding the
T3
“SETUP” key until the
D1
display will show
the wording H2o.
•
With the
E1
knob it is possible to scroll thought
the selectable parameters:
•
H2o
•
diGitAL_MEtEr
•
unit
•
StArt_ModE
•
droP _Cut
•
PLuS_ModE
•
VCut
•
VRD
•
Param_Reset (viewable only from the
generator with the separated wire fee-
der disconnected)
•
With the
E2
knob change the values.
•
Hold the
T5
key for 3s on Unitech 415-558
and the
T2
key on Unitech 328-358C and X4
wire feeder to confirm.
H2o cooling unit management
•
oFF
, water cooling unit is always disabled
(DEFAULT value)
•
on
, on demand enabling of the cooling unit
(recommended value for standard Helvi wa-
ter cooling units)
•
Aut
, cooling unit with self-recognition (value
only for special cooling units)
diGitAL_MEtEr
Setting of the seconds in which the welding para-
meters, voltage and current, are displayed after the
welding is stopped (0.0÷10.0s; def: 3.0s)
unit
Selectable in MEt (DEFAULT vaue), measurements with
metric system or iMP, measurements with imperial /
English system
StArt_ModE
Motor management during MIG striking, selectable in:
•
SFT
, active wire approach to limit sprays (DE-
FAULT value)
•
Hrd
, wire approach not active
droP _Cut
Cutting of the wire ball formed after bbt, selectable
in:
•
on
, wire ball cutting activated. It helps the
striking in MIG. (DEFAULT value)
•
oFF
, wire ball cutting not activated: Makes it
difficult to perform the MIG process.
PLuS_ModE
Selectable in:
•
Off
, the functioning of the torch trigger in 2T
and 4T remains active (DEFAULT value)
•
On
, functions in 2T, 4T, 2TP, 4TP modes get
activated.
2TP and 4TP stand for the PLUS modes, i.e. the MIG
welding with the slopes enabling.
To change the slope parameters and for correct
setting, consult your dealer.
VCut
Selectable in:
•
Aut (Automatic)
, the extinguishing voltage
varies with the set current (DEFAULT value)
•
15 V - 40 V
, fixed arc extinguishing length
•
oFF
, extinguishing voltage is the same as the
no-load voltage of the generator
VRD
Selectable in:
•
on
, no-load voltage lowered to 12 V.
•
oFF
, not lowered no-load voltage. DEFAULT
value
Param_Reset
Selectable, only by the generator with separate wire
feeder not connected, in:
•
yes
, to perform the factory reset, see section
“Factory reset”
•
no