15
MODEL
PM6 IC Storm 10
PM6 IC Storm 12
PM6 IC Storm 13
Backwash # 1 : Seconds
0:10
0:10
0:10
Draw DN # 1 : Minutes
8
12
12
*Water Usage (Gallons) sequence # 1
6.5
9.8
10.2
BACKWASH # 2 : MINUTES
12
12
12
RINSE # 2 : MINUTES
6
6
6
DRAW DN # 2 : MINUTES
8
12
12
*Water Usage (Gallons) sequence # 2
100
142
187
Maximum Service Flow Rate
4.0
6.0
7.0
Media, Cubic Feet
1
1.6
1.9
Mineral Tank Dimension
10x54
12x52
13x54
Drain Line Flow Control- GPM
5.3
7.5
10
Injector
Dk. Green
Dk. Green
Dk. Green
Max. Iron Concentration
6.0
6.0
6.0
Max. Hydrogen Sulfide Concentration
5.0
5.0
5.0
Max. Manganese Concentration
1.0
1.0
1.0
* Based upon 50 psi water pressure
require different application parameters.
Note: Manual regeneration follow sequence # 2
800591
Revised 8/12/2015
FACTORY PRESET MINUTES
** Do not use Storm filter on chlorinated water supplies.
***For levels higher than the maxium concentrations listed, contact manufacturer. Local water conditions may
PROMATE 6.0 IC STORM w/AIR REGEN SPECIFICATIONS
PROMATE 6 IC STORM WITH AIR REGEN SPECIFICATIONS
This unit is not intended to aid in the mitigation of microorganisms and is not duly registered as a pesti-
cidal device.
The Storm ozone filter must not be used on bacteriologically unsafe water supplies, such as those with
with positive Coliform or E Coli bacteria tests.