background image

11

 

101375 

Injector Cap 

1

 

102159 

O-ring 135 

1

 

102457 

Injector Screen 

1

 

102319 

Injector Assy. Z Plug-Filter 

1

 

101825 

Injector Assy. A Black 

1

 

 

101826 

Injector Assy. B Brown

 

 

101827 

Injector Assy. C Violet

 

 

101828 

Injector Assy. D Red

 

 

101829 

Injector Assy. E White

 

 

101830 

Injector Assy. F Blue

 

 

101831 

Injector Assy. G Yellow

  

101832 

Injector Assy. H Green 

 

 

101833 

Injector Assy. I Orange

 

 

101834 

Injector Assy. J Light Blue

 

 

101835 

Injector Assy K Light Green

 Not Shown  106767 

O-ring 011 

*

  Not Shown  106768 

O-ring 013 

*

QTY.

ITEM NO. ORDER NO.

DESCRIPTION

INJECTOR CAP, INJECTOR SCREEN, INJECTOR, PLUG AND O-RING

* The injector plug and the injector each contain one 011 (lower) and 013 

(upper) o-ring.
Note: For upflow position, injector is located in the up hole and injector 

plug in the down hole.  For a filter that only backwashes injector plugs are 

located in both holes.

The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench.  If necessary a pliers can be used to unscrew the nut 

or cap.  Do not use a pipe wrench to tighten or loosen nuts or caps.  Do not place screwdriver in slots on caps and/or tap with a hammer.

Do not use pipe dope or other sealants on threads.  Teflon tape must be used on threads of the 1” NPT connection and on the threads for the drain line connection.  

Teflon tape is not necessary on the nut connection nor caps because of o-rings seals.

Figure 10

REFILL AND REFILL PORT PLUG

Figure 11

**This part is required 

for backwash only 

systems.

5

6

4

2

1

ITEM NO. ORDER NO. DESCRIPTION

QTY

1

102322

Refill Port Plug Assy

1

2

101414

Elbow Locking Clip

1

4

110822

Elbow, 3/8 Assy

(Includes Check Valve & Nut)

1

5

102153

O-Ring 019

1

7

111004

Tubing 3/8" 

1

8

111006

Polytube Insert 5/16"

1

4

7

8

From Generator

Содержание PM6 IC Storm 10

Страница 1: ...er Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com STORM ProMate 6 0 Iron Curtain Storm Series p n 111701 Rev B Update...

Страница 2: ...r filter please contact the dealer who installed this system TABLE OF CONTENTS General Specifications 3 Pre Installation Check List 4 Bypass Valve Operation 4 Startup Instructions 5 Operating Conditio...

Страница 3: ...F METER Accuracy 5 Flow Rate Range 0 25 27 GPM Gallon Range 20 50 000 DIMENSIONS Drain Line 3 4 or 1 NPT Ozone Check Valve 3 8 Poly Tube ELECTRICAL CURRENT DRAW AND VOLTAGE 2 0A 120V NOTE Operating ou...

Страница 4: ...m lime and iron build up Piping that is built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment may be needed ahead of the filter to correct the pro...

Страница 5: ...ies such as those with with positive Coliform or E Coli bacteria tests Smallamountsofhardness 0 5 2gpg mayoccurinitially when filters installed on soft water Specifications Iron Storm 10 10 x54 1 0 1...

Страница 6: ...scrolled this screen will remain constant for 5 minutes then continue to scroll The condition al screens will take precedence over the scrolling and the conditional conditions will apply OR DEALER NAM...

Страница 7: ...thium battery on circuit board provides up to 2 years of time clock backup during power outages If the power is out when battery is depleted only time of day needs to be reset all other values are sto...

Страница 8: ...valve set at NORMAL on 0 E Check control valve set up procedure regeneration time option 6 Odor bleedthrough A Test for Hydrogen Sulfide H2 S on site A Hydrogen Sulfide bleedthrough 1 Increase frequen...

Страница 9: ...110543 IC Storm 13 Tank Natural Vortech Standard with Media 5 Filter Media 110544 IC Storm 10 Rebed 110545 IC Storm 12 Rebed 110546 IC Storm 13 Rebed 6 Plate Distributor Part of Vortech Tank 7 Bypass...

Страница 10: ...uttons for 3 seconds or unplug power source jack from the printed circuit board black wire and plug back in This resets the electronics and establishes the service piston position The display should f...

Страница 11: ...hole For a filter that only backwashes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a p...

Страница 12: ...for 3 4 One DLFC must be used if 3 4 fitting is used QTY ITEM NO ORDER NO DESCRIPTION Figure 12 WATER METER AND METER PLUG 1 102141 Nut 1 QC 1 2 4 102051 Meter Assy 1 3 102687 Turbine Assy 1 4 102165...

Страница 13: ...with the special plastic wrench If necessary a pliers can be used to un screw the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and o...

Страница 14: ...ce ozone Verify ozone production prior to changing CD cell to understand need for cleaning frequency at each application Initiate regeneration attach tubing to CD cell inlet and disconnect brine elbow...

Страница 15: ...0 5 0 Max Manganese Concentration 1 0 1 0 1 0 Based upon 50 psi water pressure require different application parameters Note Manual regeneration follow sequence 2 800591 Revised 8 12 2015 FACTORY PRE...

Страница 16: ...include any labor charges This paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria foul...

Отзывы: