background image

5

Start Up Instructions

pH — The pH level of the influent water must be 7.0 or higher 

for  iron  oxidation  reaction  to  proceed  per  the  engineering 

specifications.* 

Iron — This system is rated for 6.0 ppm of ferrous (clear water) 

and/or ferric (red water) iron.*

Hydrogen Sulfide — Sometimes referred to as "rotten egg" odor.  

This system is rated for 5.0 ppm hydrogen sulfide. Hydrogen 

sulfide levels vary depending on barometric pressure.*

Manganese — Limit 1.0 ppm; amounts present over 1.0 ppm may 

gradually prevent iron removal.  Note: For optimum manganese 

reduction, pH should be greater than 8.5.* 

Organic Matter (Tannins) – The presence of organic matter such 

as tannins will prevent the oxidation process of converting the 

dissolved element, such as iron or manganese, to a nonsoluble 

precipitate or solid substance.  In other words, organics can tie 

up the iron preventing filtration. The presence of organics such 

as tannins above 0.5 ppm voids any claims for this system 

to perform as stated above. In some applications, tannin 

levels below 0.5 ppm or the presence of other organics may 

hinder the operation of this system.*

Operating Conditions

Total Dissolved Solids (TDS) — While TDS does not directly 

affect iron removal, it is a good indicator of potential interference. 

Most waters have TDS less than 500 and generally present no 

problems to iron reduction. If any ion becomes excessive, it may 

cause failure of iron removal.  A TDS more than 500 ppm voids 

any claims for this system to perform as stated above.*

*For application parameters outside the specified operation 

conditions or additional information regarding the listed 

items, contact your dealer.

Do not install on chlorinated water supplies - harmful by-

products may be formed with ozone.
This unit is not intended to aid in the mitigation of microor-

ganisms and is not duly registered as a pesticidal device.

The Storm ozone filter must not be used on bacteriologi-

cally unsafe water supplies, such as those with with 

positive Coliform or E Coli bacteria tests.

Small amounts of hardness (0.5-2 gpg) may occur initially 

when filters installed on soft water.

Specifications

Iron Storm-10 

 

 

10"x54" 

1.0 

1" 

5.3

Iron Storm-12 

 

 

12"x52" 

1.6 

1" 

7.5

Iron Storm-13 

 

 

13"x54" 

1.9 

1" 

10

    

Iron Storm Models

Filter

Tank 

Size

(1)

Backwash

Rate

GPM

Max.

Service

Flow

GPM

Inlet/

Outlet

Media

Cu. Ft

(1) Water temps above 60° F will require a higher backwash rate. Consult factory.

For optimal results, allow the filter media to soak for a 

minimum of 12 hours prior to install.  This helps to main-

tain the manufacturer’s specified filtration properties. 

1.  Complete all plumbing connections; inlet, outlet and drain 

line.

2.  Place bypass valve in bypass position.  Turn on main 

water supply and open a cold filtered faucet to flush piping 

of any air and/or foreign material.  Run until water is clear.

3.  Open inlet valve slowly on bypass until it is in fully open 

service position.  Let water run to drain until clear.  Plug 

unit into 120V outlet and remove cover and plug trans-

former connection into 4-prong connection on circuit board 

labeled power.  Valve will return to service position once 

this connection is made.

4.  Let media soak for 15 minutes before proceeding.

5.  Initiate backwash by holding “REGEN” button down until 

piston movement is heard.  

6.  Let backwash continue until cycle is done.  When “RINSE” 

is displayed, push the REGEN button again to move into 

the SERVICE position.  Let the system settle for 5 minutes.

7.  Repeat the backwash and settle steps (5&6) for a total of 

three times.

NOTE: It takes several backwash cycles before all the media 

fines are removed.  Elimination of the 12 hour soak procedure 

may result in more backwash cycles required to remove the 

media fines.

Failure to follow proper start-up may result in 

equipment malfunction not covered by warranty.

Iron Applications

0.3 - 2.0 ppm Iron - Every 3rd Day
2.0 - 4.0 ppm Iron - Every Other Day
4.0 - 6.0 ppm Iron - Every Day

Backwash Frequency

Hydrogen Sulfide Applications

0.1 - 1.0 ppm Hydrogen Sulfide - 100 Gallon
1.0 - 5.0 ppm Hydrogen Sulfide - 50 Gallon

Ozone Recharge Frequency

Содержание PM6 IC Storm 10

Страница 1: ...er Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com STORM ProMate 6 0 Iron Curtain Storm Series p n 111701 Rev B Update...

Страница 2: ...r filter please contact the dealer who installed this system TABLE OF CONTENTS General Specifications 3 Pre Installation Check List 4 Bypass Valve Operation 4 Startup Instructions 5 Operating Conditio...

Страница 3: ...F METER Accuracy 5 Flow Rate Range 0 25 27 GPM Gallon Range 20 50 000 DIMENSIONS Drain Line 3 4 or 1 NPT Ozone Check Valve 3 8 Poly Tube ELECTRICAL CURRENT DRAW AND VOLTAGE 2 0A 120V NOTE Operating ou...

Страница 4: ...m lime and iron build up Piping that is built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment may be needed ahead of the filter to correct the pro...

Страница 5: ...ies such as those with with positive Coliform or E Coli bacteria tests Smallamountsofhardness 0 5 2gpg mayoccurinitially when filters installed on soft water Specifications Iron Storm 10 10 x54 1 0 1...

Страница 6: ...scrolled this screen will remain constant for 5 minutes then continue to scroll The condition al screens will take precedence over the scrolling and the conditional conditions will apply OR DEALER NAM...

Страница 7: ...thium battery on circuit board provides up to 2 years of time clock backup during power outages If the power is out when battery is depleted only time of day needs to be reset all other values are sto...

Страница 8: ...valve set at NORMAL on 0 E Check control valve set up procedure regeneration time option 6 Odor bleedthrough A Test for Hydrogen Sulfide H2 S on site A Hydrogen Sulfide bleedthrough 1 Increase frequen...

Страница 9: ...110543 IC Storm 13 Tank Natural Vortech Standard with Media 5 Filter Media 110544 IC Storm 10 Rebed 110545 IC Storm 12 Rebed 110546 IC Storm 13 Rebed 6 Plate Distributor Part of Vortech Tank 7 Bypass...

Страница 10: ...uttons for 3 seconds or unplug power source jack from the printed circuit board black wire and plug back in This resets the electronics and establishes the service piston position The display should f...

Страница 11: ...hole For a filter that only backwashes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a p...

Страница 12: ...for 3 4 One DLFC must be used if 3 4 fitting is used QTY ITEM NO ORDER NO DESCRIPTION Figure 12 WATER METER AND METER PLUG 1 102141 Nut 1 QC 1 2 4 102051 Meter Assy 1 3 102687 Turbine Assy 1 4 102165...

Страница 13: ...with the special plastic wrench If necessary a pliers can be used to un screw the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and o...

Страница 14: ...ce ozone Verify ozone production prior to changing CD cell to understand need for cleaning frequency at each application Initiate regeneration attach tubing to CD cell inlet and disconnect brine elbow...

Страница 15: ...0 5 0 Max Manganese Concentration 1 0 1 0 1 0 Based upon 50 psi water pressure require different application parameters Note Manual regeneration follow sequence 2 800591 Revised 8 12 2015 FACTORY PRE...

Страница 16: ...include any labor charges This paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria foul...

Отзывы: