InstallatIon InstructIons
Pergoline
2.9. mounting the DiStanCe tube(S):
2.10. alignment oF the SyStem
•
Align the system by moving the casing in the brackets or
sideways movement of the two posts in the diagonal.
Deviations of the diagonal measurements by more than
5 mm may result in malfunctions.
•
Vertically align the posts
To stabilise the parallelism of the system, mount at least
one distance tube before aligning the system at the post.
•
Insert the washer and turn the distance tube holder into
the end cap of the distance tube until it is fully in.
•
Align the tightening surfaces of both holders.
•
Secure the holders in the guide rails with screws and
hammerhead threaded plates.
The writing on the hammerhead threaded plates must
point towards the surface of the holder.
•
The position depends on the extended length of the
system. Up to an extended length of 3500mm near the
posts, from 3501mm extended length distributed evenly
over the length of the guide rails.
The position of the distance tubes can also be adjusted
to the cross seams of the fabric.
•
Distribute additional distance tubes over the length
of the guide rails.
To fasten the distance tube holders, push the screws with
the hammerhead threaded plates up and twist (as described
in 2.8.). Ensure that the hammerhead threaded plates have
twisted correctly in the installation channel.
•
After tightening, the longer diagonal must be crosswise
to the clamping channel of the guide rail (see drawing
next to the text).
•
Lock the nuts against the end caps of the distance tube.
parallelism rear
parallelism front
diagonal
dia
go
na
l
2.8. MOUNTING THE DISTANCE TUBE(S):
i
• To stabilise the parallelism of the system, mount at
least one distance tube before aligning the system at
the post.
• Insert the washer and turn the distance tube holder
into the end cap of the distance tube until it is fully in.
• Align the tightening surfaces of both holders.
• Secure the holders in the guide rails with screws and
hammerhead threaded plates.
i
• The writing on the hammerhead threaded plates
must point towards the surface of the holder.
• The position depends on the extended length of the
system. Up to an extended length of 3500mm near
the posts, from 3501mm extended length distributed
evenly over the length of the guide rails. The position
of the distance tubes can also be adjusted to the
cross seams of the fabric.
• Distribute additional distance tubes over the length of
the guide rails.
i
• To fasten the distance tube holders, push the screws
with the hammerhead threaded plates up and twist
(as described in 2.8.). Ensure that the hammerhead
threaded plates have twisted correctly in the
installation channel.
• After tightening, the longer diagonal must be
crosswise to the clamping channel of the guide rail
(see drawing next to the text).
• Lock the nuts against the end caps of the distance
tube.