background image

ACCESSORIES

Please notice our extensive range of reflectors, umbrellas, softboxes, stands and other accessories.
Visit us on

www.hedler.com

HEDLER WARRANTY

All HEDLER equipment is fully guaranteed against any material or manufacturing defects for three years after date of purchase. Parts made out 
of glass, fuses, halogen bulbs, flash tubes, Pyrex

®

 coverings and single cell LED modules are not covered by this warranty.

MAINTENANCE and REPAIR

For a secure operation of light units they have to be maintained. Therefore: before using light units they have to be checked visually and an 
electrical safety check has to be done every twelve month. The results of this check have to be documented and archived. If wou have any 
questions about the safety check, please feel free to contact us.

0049 (0)6482-918100
[email protected]

If repair is required, please, contact your dealer, the authorized distributor in your country or the HEDLER factory directly. Please note, that a 
pre-dismantled light unit could cause increased repair costs.

CHECK

All HEDLER light units are tested at HEDLER Systemlicht GmbH according to DIN 0701/0702 with protocol I.
This check has to be repeated yearly.
Please contact us

0049 (0)6482-918100
[email protected]

PLEASE NOTE - SPECIAL SET-UP ADVICE

The light units of the HEDLER Profilux

®

 LED range has an upside and an underside, setting-up the light unit it is important to take care of the 

correct position of these sides. The light unit is set-up correctly, if the QuickFit Adapter (located at the front side of the housing) is located 
beneath the safety glass / bulb respectively the Fresnel lens.

To ensure a continuous operation, the light units of the HEDLER Profilux

®

 LED range has to be set-up / operated in the position described 

respectively as shown on the photograph.

If you take the light unit in operation in an upside-down set-up, the internal automatic temperature safety switch will (according to the ambient 
conditions) switch off the light unit after some operation time until it has cooled down. This is not a failure or a maloperation of the light unit of, 
it is a protection shutoff for the internal electronic ballast to prevent overheating.

H E D L E R   S y s t e m l i c h t   G m b H       H e e r s t r a s s e   1 1 2       D - 6 5 5 9 4   R u n k e l   /   L a h n       w w w . h e d l e r. c o m
Te l e f o n   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 0 0       Te l e f a x   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 1 1       e M a i l   i n f o @ h e d l e r. c o m

Profilux

®

 LED

1400

 / Profilux

®

 LED

1400

 DMX

HEDLER

®

S y s t e m l i c h t

OPERATION MANUAL

Set-up correctly - shown for the HEDLER 
Profilux

®

 LED

1400

 with optional 4-Leaf 

barndoor 360° attached.

Содержание Profilux LED 1400

Страница 1: ...sy compatibility of all HEDLER lioghtformers Interchangeable reflectors with bayonet ring can be attached in the following way Interchangeable reflectors with bayonet ring can be attached in the follo...

Страница 2: ...ATION MANUAL KEY BUTTONS On the back of the light units of the HEDLER Profilux LED range there are several key buttons By pressing them the indicated functions will be switched alternatingly Fan 100 A...

Страница 3: ...ly After replacing the Fresnel lens tighten its securing screws hand tight Attach the front plate at the housing and tighten the front plates four securing screws Please before taking the HEDLER Profi...

Страница 4: ...nfo hedler com PLEASE NOTE SPECIAL SET UP ADVICE The light units of the HEDLER Profilux LED range has an upside and an underside setting up the light unit it is important to take care of the correct p...

Страница 5: ...nit s in hospital s museum s factory factories asf with permission of the appropriate responsible public authority administration company management or business management only If not taking care of t...

Страница 6: ...use a Hedler light unit with a defective safety glass a defective Pyrex cover a defective flash bulb defective bulb s and or defective fuse s Never put a Hedler light unit into operation with a defec...

Страница 7: ...flectors parts of softboxes and reflex umbrellas and some accessories completely after using them and before packing them away not doing so can cause serious burnig and or the risk of sparking Not use...

Отзывы: