Service

A blinking of this LED indicates that the HEDLER Profilux

®

 LED

1400

 light unit model was in operation for 6000 hours. The light unit should be send 

to HEDLER Systemlicht GmbH for recalibration. Please contact HEDLER Systemlicht GmbH directly or contact your photographic specialized 
dealer.
0049 (0)6482-918100
[email protected]

Power

A continuous glowing of this LED indicates the light unit is switched on.

Cooling

A continuous glowing of this LED indicates the fan cooling is functional.

LED

The light units of the HEDLER Profilux

®

 LED range are equipped with one 185 W high power single cell LED with 138 lm/W, which can´t be 

replaced by the user. If any technical failure of the LED takes place please contact HEDLER Systemlicht GmbH or your photographic specialized 
dealer.
0049 (0)6482-918100
[email protected]

FRESNEL LENS

To replace the Fresnel lens: please, make sure that the housing of the HEDLER Profilux

®

 LED

1400

 / HEDLER Profilux

®

 LED

1400

 DMX has cooled off 

before interchanging the Fresnel lens, otherwise there is a risk of burning! Always disconnect the HEDLER Profilux

®

 LED

1400

 / HEDLER Profilux

® 

LED

1400

 DMX from the power supply before interchanging the Fresnel lens. Unscrew the four socket screws of the housings front plate and 

remove the front plate with the Fresnel lens. Unscrew the securing screws of the Fresnel lens and replace the defective one with an original 
HEDLER Fresnel lens only. After replacing the Fresnel lens tighten its securing screws hand-tight. Attach the front plate at the housing and tighten 
the front plates four securing screws. Please, before taking the HEDLER Profilux

®

 LED

1400

 / HEDLER Profilux

®

 LED

1400

 DMX in operation, make 

sure that the front plate is mounted correctly!

FOCUSING

To focus the HEDLER Profilux

®

 LED

1400

 or the HEDLER Profilux

®

 LED

1400

 DMX light beam turn the focusing knob anti clock-wise (increased 

spotlight characteristic) or clock-wise (increased floodlight characteristic) to adjust the light beams size.

DMX

At the back of the HEDLER Profilux

®

 LED

1400

 DMX light unit there are two 5-pin DMX-sockets with standard pin configuration. Connected 

to a suitable DMX controller the light units can be switched on / off and the light output power can be adjusted remotely. The upper DMX 
connect is used for the forementioned operations of the light unit. The lower DMX connect is used to connect another light unit and works as a 
„passthrough feature“ for the DMX-signal. Setting the DMX-address of the respectively light unit is done directly at the light unit, no additional 
accessory is needed.

Setting the DMX-address will be done as follows: a) HEDLER Profilux

®

 LED

1400

 DMX must be connected to a power supply and switched off;    

b) press the key button Dimmer OFF / ON for approx. 3 seconds or until „A--“ is displayed and don´t release the key button; c) pressing the 
key button Fan 100% / Automatic or POWER OFF / ON once the numerical address of the light unit will be increased / decreased by one; d) to 
quit the process release the key button Dimmer OFF / ON.

DMX-pin configuration of the HEDLER Profilux

®

 LED

1400

 DMX (front view)

HEDLER

®

S y s t e m l i c h t

OPERATION MANUAL

5 pin XLR plug

1 - earth/shielding 

2 - DMX-   

3 - DMX+
4 - optional 2nd bus system - DMX-
5 - optional 2nd bus system - DMX+

5 pin XLR socket

1 - earth/shielding 

2 - DMX-   

3 - DMX+
4 - optional 2nd bus system - DMX-
5 - optional 2nd bus system - DMX+

Содержание Profilux LED 1400

Страница 1: ...sy compatibility of all HEDLER lioghtformers Interchangeable reflectors with bayonet ring can be attached in the following way Interchangeable reflectors with bayonet ring can be attached in the follo...

Страница 2: ...ATION MANUAL KEY BUTTONS On the back of the light units of the HEDLER Profilux LED range there are several key buttons By pressing them the indicated functions will be switched alternatingly Fan 100 A...

Страница 3: ...ly After replacing the Fresnel lens tighten its securing screws hand tight Attach the front plate at the housing and tighten the front plates four securing screws Please before taking the HEDLER Profi...

Страница 4: ...nfo hedler com PLEASE NOTE SPECIAL SET UP ADVICE The light units of the HEDLER Profilux LED range has an upside and an underside setting up the light unit it is important to take care of the correct p...

Страница 5: ...nit s in hospital s museum s factory factories asf with permission of the appropriate responsible public authority administration company management or business management only If not taking care of t...

Страница 6: ...use a Hedler light unit with a defective safety glass a defective Pyrex cover a defective flash bulb defective bulb s and or defective fuse s Never put a Hedler light unit into operation with a defec...

Страница 7: ...flectors parts of softboxes and reflex umbrellas and some accessories completely after using them and before packing them away not doing so can cause serious burnig and or the risk of sparking Not use...

Отзывы: