2.  Mark screws locations on wall.
3.  Remove heater from mounting bracket.
4.  If installing bottom mounting screw into hollow 

or solid wall, install wall anchors. Follow steps 

1 through 4 under Attaching to Wall using 

Anchor. If installing bottom mounting screw into 

wall stud, drill holes at marked locations using 

9/64” drill bit.

5.  Re-place heater onto mounting bracket.
6.  Place spacers between bottom mounting holes 

and wall anchor or drilled hole.

7.  Hold spacer in place with one hand. With the 

other hand, insert mounting screw through 

bottom mounting hole and spacer. Place tip of 

screw in opening of wall anchor or drilled hole.

8.  Tighten both screws until heater is firmly 

secured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. 

Replace front panel after making gas connections 

and checking for leaks.

Floor MOUNTING AWAY FROM WALL

Installing Support Feet (See figure 11.)

1.  Lay heater onto table on its back with bottom 

edge overhanging table edge.

2.  Securely attach feet to bottom of heater using 

2 – self-tapping screws each.

Figure 11

Note: Feet should have long end going out the 

front of heater, and the edge coinciding with side of 

heater. If feet overhang side of the heater, switch 

leg location.
3.  Place heater on non-combustible surface (see 

Locating Heater, page 6) before proceeding 

with gas connection. If this will be a permanent 

location, heater may be locked into position 

using anchoring holes in mounting feet.

Note: Use of floor mounting feet will require 

you to use a 3/8 NPT street elbow to make gas 

connection.

CONNECTING TO GAS SUPPLY

WARNING:

 A qualified service person must connect 

heater to gas supply. Follow all local codes. 

WARNING:

 This appliance requires a 3/8” NPT 

(National Pipe Thread) inlet connection to the 

pressure regulator. Use of floor mounting feet will 

require you to use a 3/8 NPT street elbow to make 

gas connection. 

CAUTION: Never connect heater directly to the 

Propane supply. This heater requires an external 

regulator.(which is attached to the supplied hose). 

Install the external regulator between the heater and 

Propane/LP supply. 
The external regulator will reduce the incoming gas 

pressure to between 11 and 14 inches of water. If 

you do not reduce incoming gas pressure heater 

regulator damage could occur. Install external 

regulator with the vent pointing down. Pointing the 

vent down protects it from freezing rain or sleet.

CAUTION:

 Use only new black iron or steel pipe. 

Internally-tinned copper tubing may be used in certain 

areas. Check your local codes. Use pipe of larger 

enough diameter to allow proper gas volume to heater. 

If pipe is too small, undue loss of pressure will occur. 

Installation must include an equipment shutoff valve, 

union and plugged 1/8” NPT tap. Locate NPT tap within 

reach of test gauge hookup. NPT tap must be upstream 

from heater (see figure 12).
*A CSA/AGA certified equipment shutoff valve with 

1/8” NPT tap is an acceptable alternative to test gauge 

connection. Purchase the CSA/AGA certified equipment 

shutoff valve from your dealer. 

IMPORTANT:

 Install an equipment shutoff valve in an 

accessible location. The equipment shutoff valve is for 

turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will 

prevent excess sealant from going into pipe. Excess 

sealant in pipe could result in clogged heater fuel train.

CAUTION:

 Use pipe joint sealant that is resistant to 

LP-Gas

Install sediment trap in supply line as shown in figure 

12. Locate sediment trap where it is within reach 

for cleaning. A sediment trap traps moisture and 

contaminants. This keeps them from going into heater. 

If sediment trap is not installed or is installed improperly, 

heater may not run correctly.

IMPORTANT:

 Hold pressure regulator with wrench 

when connecting it to gas piping and/or fittings.

CHECKING GAS CONNECTIONS

WARNING:

 Test all gas piping and connections for 

leaks after installing or servicing. Correct all leaks 

at once. 

Screw  

hole

Screw  

hole

Содержание HSSVFBF10LPT

Страница 1: ...ot use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Insta...

Страница 2: ...conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous Do not place clothing or other fla...

Страница 3: ...r If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liqui...

Страница 4: ...maller than defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code...

Страница 5: ...space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You...

Страница 6: ...18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next...

Страница 7: ...s firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting scr...

Страница 8: ...NPT street elbow to make gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator which is attached to the supplied hose Install the extern...

Страница 9: ...ipment shutoff valve see figure 12 2 Pressurize supply piping system by either using compressed air or opening propane LP supply valve 3 Check all joints from the propane LP supply valve to equipment...

Страница 10: ...smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 se...

Страница 11: ...p the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the bl...

Страница 12: ...Replace thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner...

Страница 13: ...ng Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing a...

Страница 14: ...ocouple LP 1 21 80019 Ignitor Pulse 1 8 80017 Burner Assembly 1 22 80014 Ignitor Wire 1 9 80009 Orifice 1 23 8001 1 Ignitor Bracket 1 10 N A Burner Right Bracket 1 24 80010 Thermostat Valve Mounting B...

Страница 15: ...DESCRIPTION QTY 1 80040 Wire Guard 1 1 1 N A Regulator Connection 1 2 80051 Front Panel 1 12 80058 Floor Mounting Feet 1 3 80024 Reflector 1 13 80052 Back Panel 1 4 80030 Burner Assembly 1 14 80036 Wa...

Страница 16: ...00 PM EST Monday through Friday Please include the model number date of purchase serial number and description of problem in all communication LIMITED WARRANTY Enerco Group Inc EGI warrants Heatstar...

Отзывы: