HeatStar HSSVFBF10LPT Скачать руководство пользователя страница 11

11

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

• 

Turn heater off (see 

To Turn OFF Gas to 

Appliance

, page 10.

 

• 

See Troubleshooting, pages 12-13.

CLEANING AND MAINTENANCE

WARNING:

 Turn off heater and let cool before 

servicing. 

CAUTION:

 You must keep control areas, burner and 

circulation air passageways of heater clean. Inspect 

these areas of heater before use. Have the heater 

inspected yearly by a qualified service person. Heater 

may need more frequent cleaning due to excess lint 

from carpeting, bedding material, pet hair, etc. 
Make sure grille guard is in place before running 

heater. If screen or grille guard is removed for servicing 

it must be replaced prior to operating the heater. 

WARNING:

 Failure to keep the primary air 

opening(s) of the burner(s) clean may result in 

sooting and property damage. 

CLEANING ODS/PILOT AND BURNER

• 

Use as vacuum cleaner, pressurized air or 

small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit every 2,500 

hours of operation or every three months. We also 

recommend that you keep the burner tube and pilot 

assembly clean and free of dust and dirt. To clean these 

parts we recommend using compressed air no greater 

than 30 psig.
This can be done by using a vacuum cleaner in the 

blow position, using compressed air in a can, please 

follow the directions on the can. If you don’t follow 

directions on the can you could damage the burner or 

pilot assembly. In addition, the directions that follow 

should also be followed.

1.  Shut off the unit, including the pilot. Allow the 

unit to cool for at least thirty minutes.

2.  Inspect burner and pilot for dust and dirt.
3.  Blow air through the port/slots and holes in the 

burner.

Figure 16

Correct pilot position.

Incorrect pilot position.5

Pilot Air Inlet Hole

Pilot Assembly

Figure 17

A yellow tip on the pilot flame indicates dust and dirt in 

the pilot assembly. To clean the pilot assembly find the 

small pilot air inlet hole about two inches from where 

the pilot flame comes out of the pilot assembly (see 

Figure 17). With the unit off, lightly blow air through the 

air inlet hole. You may blow through a drinking straw if 

compressed air is not available.

CLEANING HEATER CABINET

Air passageways

• 

Use a vacuum cleaner or pressurized air to 

clean

Exterior

• 

Use a soft cloth dampened with a mild soap 

and water mixture. Wipe the cabinet to remove 

dust.

Содержание HSSVFBF10LPT

Страница 1: ...ot use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Insta...

Страница 2: ...conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous Do not place clothing or other fla...

Страница 3: ...r If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liqui...

Страница 4: ...maller than defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code...

Страница 5: ...space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You...

Страница 6: ...18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next...

Страница 7: ...s firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting scr...

Страница 8: ...NPT street elbow to make gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator which is attached to the supplied hose Install the extern...

Страница 9: ...ipment shutoff valve see figure 12 2 Pressurize supply piping system by either using compressed air or opening propane LP supply valve 3 Check all joints from the propane LP supply valve to equipment...

Страница 10: ...smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 se...

Страница 11: ...p the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the bl...

Страница 12: ...Replace thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner...

Страница 13: ...ng Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing a...

Страница 14: ...ocouple LP 1 21 80019 Ignitor Pulse 1 8 80017 Burner Assembly 1 22 80014 Ignitor Wire 1 9 80009 Orifice 1 23 8001 1 Ignitor Bracket 1 10 N A Burner Right Bracket 1 24 80010 Thermostat Valve Mounting B...

Страница 15: ...DESCRIPTION QTY 1 80040 Wire Guard 1 1 1 N A Regulator Connection 1 2 80051 Front Panel 1 12 80058 Floor Mounting Feet 1 3 80024 Reflector 1 13 80052 Back Panel 1 4 80030 Burner Assembly 1 14 80036 Wa...

Страница 16: ...00 PM EST Monday through Friday Please include the model number date of purchase serial number and description of problem in all communication LIMITED WARRANTY Enerco Group Inc EGI warrants Heatstar...

Отзывы: