![HeatStar HSSVFBF10LPT Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/heatstar/hssvfbf10lpt/hssvfbf10lpt_operating-instructions-and-owners-manual_2117841003.webp)
3
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
DANGER
: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble
the flu, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
Product Features
Figure 1
PRECAUTIONS:
1. 10,000 BTU may be installed in a bedroom, but not
a bathroom, or any place where a strong wind would
shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS) safety
shutoff system shuts down the heater if not enough
fresh air is available. See
Fresh Air for Combustion
and Ventilation
, page 5.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and let cool before servicing. Only a qualified
service person should service and repair heater.
6. Do not run heater:
•
Where flammable liquids or vapors are used or stored
•
During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder
residue within burner box or on adjacent walls or
furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to
inspect the room heater and to replace any part of
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
Control Knob
Grill
Front Panel
Burners
Heater
Cabinet
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**
SPECIFICATIONS
MODEL
HSSVFRD10LPT
HSSVFBF10LPT
BTU (Available)
10,000
10,000
Type of Gas
LP-Gas Only
LP-Gas Only
Ignition
Electronic Pulse (AA Battery)
Electronic Pulse (AA Battery)
Pressure Regulator Setting
10 Inches of Water
10 Inches of Water
Inlet Gas Pressure (Maximum)
14 Inches of Water
14 Inches of Water
Inlet Gas Pressure (Minimum)
11 Inches of Water
11 Inches of Water
Burners / Orifice nozzles
2
1
Thermostatic Control
Yes
Yes
Clearances: inches (mm)
Top
36” (915cm)
36” (915cm)
Sides
10” (254cm)
10” (254cm)
Floor (min. to top of carpet)
3” (76cm)
3” (76cm)
Fabric / flammable objects
36” (915cm)
36” (915cm) 36” (915cm)