3. TECHNICAL SPECIFICATION
SPECIFICATIONS
MODEL
150T/60
k
W
300T/120
k
W
Mode Type
Heat & Cool
Discharge
Top
Fan Quantity
1
2
Performance at Air 26°C, Water 26°C, Humidity 80%
Heat Capacity
kW
60.0
120.0
COP
6.2-16.1
6.0-16.2
Performance at Air 15°C, Water 26°C, Humidity 70%
Heat Capacity
kW
40.0
81.0
COP
4.6-8.1
4.8-8.1
General
Rated input power at air 15°C
kW
1.0-8.7
2.0-16.8
Rated input current at air
15°C
Amps
1.5-12.6
2.9-24.2
Circuit Breaker
Amps
25.0
50.0
Power Supply
380v / 50Hz / 3PH
Pool Volume - Cold Climate
Litres
≤100,000
≤200,000
Pool Volume - Warm Climate
Litres
≤200,000
≤400,000
Advised Flow Rate
L/min
375
750
Inlet / Outlet
mm
75
90
Compressor
Twin-rotary Mitsubishi DC inverter
Heat Exchanger
Spiral titanium tube in PVC
Casing
Black aluminum-alloy
Weight / Dimensions
Net Weight
kg
290
490
Net Dimensions L x W x H
mm
1000 x 1110 x 1260
2100 x 1090 x 1280
The sizing of heat pumps are based on pool volume for seasonal swimming with the use of a Heatseeker Diamond Pool Cover.
1.
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover.
2.
Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
09
Содержание VORTEXC
Страница 1: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 1 INSTALLATION USER MANUAL...
Страница 29: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 27...
Страница 30: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 28...
Страница 31: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 29...
Страница 32: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 30 supremeheating com au 1300 787 978...