background image

INSTALLATION & USER MANUAL

FOR USERS

1. 

General information

02

  1.1. Contents

02

 

1.2. 

Operating conditions and range

02

 

1.3. 

Advantages of different modes

02

 

1.4. 

Kind reminder

03

2. Operation

06

 

2.1. 

Notice before using

06

 

2.2.  Operation instructions

06

 

2.3.  Daily maintenance and winterizing

08

3. 

Technical specification

09

FOR INSTALLERS AND PROFESSIONALS

4. Transportation

10

5. 

Installation and maintenance

11

 

5.1. 

Notice before installation

11

 

5.2.  Installation instructions

12

 

5.3.  Trial after installation

17

6. 

Trouble shooting for common faults

18

7. 

Error codes

19

ANCILLARY PRODUCTS

8. VortexSwitch

20

 

8.1. Operation

20

 

8.2.  Heating priority

20

 

8.3.  Installation instructions

21

9. VortexLink

22

 

9.1. Operation

22

 

9.2.  Heat demand

22

 

9.3.  Installation instructions

23

WARRANTY

11. 

Warranty agreement

24

Heatseeker VortexC Inverter Heat Pump 

Installation & User Manual

01

Содержание VORTEXC

Страница 1: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 1 INSTALLATION USER MANUAL...

Страница 2: ...eaton Grange NSW 2567 P 02 4648 4766 M 0448 959 666 M 0438 471 381 solar nsw supremeheating com au salesnsw supremeheating com au QLD Office Unit 13 53 57 Link Drive Yatala QLD 4207 P 07 3807 6308 F 1...

Страница 3: ...RS AND PROFESSIONALS 4 Transportation 10 5 Installation and maintenance 11 5 1 Notice before installation 11 5 2 Installation instructions 12 5 3 Trial after installation 17 6 Trouble shooting for com...

Страница 4: ...ump will have ideal performance in the operation range Air 15 C 25 C 1 3 ADVANTAGES OF DIFFERENT MODES The heat pump has two modes Smart and Silence They have different advantages under different cond...

Страница 5: ...he heat pump can only be used with pool water It can NEVER be used to heat or cool other flammable or turbid liquid 1 4 2 When moving the heat pump do not lift the water union This will damage the tit...

Страница 6: ...not store or use combustible gas or liquids such as thinners paints or fuels near the heat pump 1 4 6 If you detect any abnormal noises odours smoke or leaks from the heat pump immediately switch off...

Страница 7: ...following codes are not failures CODES No water flow Anti freezing reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal HeatseekerVortexC Inverter Heat Pump Insta...

Страница 8: ...TION Power ON OFF Press to power on or off the heat pump Up Down Press to set desired water temperature Heat Cool Auto Press to switch between cooling heating and auto Fan Press to select Silence mode...

Страница 9: ...press to confirm 3 After entering the Timer ON OFF setting press directly without adjusting the time to cancel the relevant Timer setting 4 If no settings are made within 30 seconds any changes will...

Страница 10: ...reaches sub zero temperatures please disconnect from power supply and drain water out of the heat pump When using the heat pump under 2 C make sure there is always water flow Important Unscrew the wa...

Страница 11: ...Warm Climate Litres 200 000 400 000 Advised Flow Rate L min 375 750 Inlet Outlet mm 75 90 Compressor Twin rotary Mitsubishi DC inverter Heat Exchanger Spiral titanium tube in PVC Casing Black aluminu...

Страница 12: ...e heat pump please ensure the unit remains in an upright position at all times 4 2 When moving the heat pump do not lift the water union This will damage the titanium heat exchanger HeatseekerVortexC...

Страница 13: ...ssional Unqualified installations may result in damage to the heat pump and or safety risks to the user 5 1 NOTICE BEFORE INSTALLATION 5 1 1 Plumbing connections must be made with solid PVC pipe Usage...

Страница 14: ...should be installed in a place with good ventilation Do not obstruct the air inlet or outlet ofthe heat pump The efficiency may be reduced or even stopped Minimum distance 1 Filter 2 Water processor 3...

Страница 15: ...W 1000 660 1110 1070 1000 780 105 1260 E B F G D A H C MODEL UNIT MM A B C D E F G H VortexC 300T 120kW 1000 1630 1090 1050 2100 515 140 1280 Above data is subject to modification without notice Heats...

Страница 16: ...ng protecting devices and cable specification 1 Connect to appropriate power supply The voltage should comply with the rated voltage of the unit 2 Earth the machine well 3 Wiring must be handled by a...

Страница 17: ...two screws inside Step 5 Pass the power cord through the three holes Step 7 Fix the internal panel by using the two screws removed previously Step 4 Open the internal Step 6 Restore the internal pane...

Страница 18: ...For your safe use in winter it s strongly recommended to equip heating priority function Distribution Box Customer prepare Power Cord Swimming Pool Heat Pump Wiring Board Power Supply 400V 50Hz Break...

Страница 19: ...he user is advised to start the water pump before the heat pump and turn off the heat pump before the water pump for long life circle 2 The user should start the water pump and check for any leakage o...

Страница 20: ...obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If a...

Страница 21: ...P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P...

Страница 22: ...ode Every 60 minutes the circulation pump is started for 2 minutes to sample the water temperature If after 2 minutes the temperature of the water is below above the required set point temperature dep...

Страница 23: ...le is 1 8m long and should be plugged directly into a general power outlet not into an extension lead 8 3 2 Pump The circulation pump plugs into the 240V outlet beneath the VortexSwitch 8 3 3 Heating...

Страница 24: ...t such a time can t be sufficient sometimes to maintain the water at the desired temperature depending on the seasons This is the reason why the heat pump is equipped with the sample function that wil...

Страница 25: ...n mind that the power cable is 1 8m long and should be plugged directly into a general power outlet not into an extension lead 9 3 2 Pump The filtration pump plugs into the 240V outlet beneath the Vor...

Страница 26: ...mited warranty from Supreme Solar Pty Ltd 2 19 Enterprise Drive Bundoora Victoria 3083 Phone 03 9460 4200 Email info supremeheating com au In field labour warranty is applicable in Capital City Metrop...

Страница 27: ...ould otherwise be implied in this agreement or in relation to the Product is hereby excluded 9 Where legislation implies in this agreement or in relation to the Product any condition or warranty and t...

Страница 28: ...3 4 5 and 6 Whole agreement 15 This warranty and any warranties implied by law which are not capable of being excluded or modified from the whole warranty agreement between Supreme Solar Pty Ltd and...

Страница 29: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 27...

Страница 30: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 28...

Страница 31: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 29...

Страница 32: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 30 supremeheating com au 1300 787 978...