5.3. TRIAL AFTER INSTALLATION
ATTENTION
Please check all the wirings carefully before turning on the heat pump.
5.3.1 Inspection before use
1.
Check installation of the whole heat pump and the pipe connections according to the pipe
connecting drawing;
2.
Check the electric wiring according to the electrical wiring diagram and earthing connection;
3.
Make sure that the main power is well connected;
4.
Check if there is any obstacle in front of the air inlet and outlet of the heat pump
5.3.2. Trial
1.
The user is advised to start the water pump before the heat pump, and turn off the heat
pump before the water pump for long life circle.
2.
The user should start the water pump, and check for any leakage of water; power on and
press the ON/OFF button of the heat pump, and set desired temperature in the thermostat.
3.
In order to protect the heat pump, the heat pump is equipped with start delay function. When
starting the heat pump, the fan will start to run in 3 minutes, in another 30 seconds, the
compressor will start to run.
4.
After pool heat pump starts up, check for any abnormal noise from the heat pump.
5.
Check the temperature setting
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
17
Содержание VORTEXC
Страница 1: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 1 INSTALLATION USER MANUAL...
Страница 29: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 27...
Страница 30: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 28...
Страница 31: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 29...
Страница 32: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 30 supremeheating com au 1300 787 978...