8. VORTEX SWITCH
8.1 OPERATION
The VortexSwitch is designed to switch a 240Vac pump maximum rated to 9.98 Amps 2395 watts
from the switch inputs. This unit is designed to be plugged into a general power outlet and the
heating priority connections on the heat pump.
8.2 HEATING PRIORITY
The heat pump is designed to heat or cool the water of the pool only when the water circulates
through it. By connecting the VortexSwitch to the heat pump, and then the circulation pump to the
VortexSwitch, the heat pump will control when the circulation pump is run. This system allows the
heat pump to maintain the set-point temperature in either heating or cooling mode.
Every 60 minutes, the circulation pump is started for 2 minutes to sample the water temperature.
If after 2 minutes, the temperature of the water is below/above the required set-point temperature
(depending if in heating or cooling mode), the circulation pump will be turned off for a further 60
minutes before sampling the water temperature again.
If the heat pump senses that the water has cooled/heated below/above the temperature set-
point, the circulation pump and the heat pump will continue to operate until the desired set-point
temperature is reached.
By following the instructions in the heat pump instruction manual, setting a start and stop time will
ensure that the heat pump is not sampling the water temperature and running throughout the
night if running noise is a factor.
Heatseeker VortexC Inverter Heat Pump
Installation & User Manual
20
Содержание VORTEXC
Страница 1: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 1 INSTALLATION USER MANUAL...
Страница 29: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 27...
Страница 30: ...NOTES HeatseekerVortexC Inverter Heat Pump Installation User Manual 28...
Страница 31: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 29...
Страница 32: ...HeatseekerVortexC Inverter Heat Pump Installation User Manual 30 supremeheating com au 1300 787 978...