28
Feature 03 - Frost Protect: You can set whether the
thermostat will maintain the frost temperature when the
thermostat display is turned off. As a default, this is enabled.
Feature 04 – Frost Protect Temperature: This is the
temperature maintained when the thermostat is in frost
mode. The range is 07-17°C. The default is 12°C and is
suitable for almost all applications.
Feature 05 – Output Delay: To prevent rapid switching, an
output delay can be entered. This can be set from 00-15
minutes. The default is 00 which means there is no delay.
Feature 06 – UH1-W or RC1-W Receiver: The thermostat
can work with our UH1-W or RC1-W. This setting
determines which is being used. 00 = UH1-W, 01 = RC1-W
Feature 07 – Receiver Address: Within one building, up
to 9 UH1-W’s or 32 RC1-W receivers can be used. Each
receiver must have a unique receiver address.
Feature 08 – Zone Number: This is the zone number you
are assigning the thermostat to on either the UH1-W or the
RC1-W receiver. 01-08 - UH1-W, 01-02 – RC1-W