26
25
Wireless
Series
Model
: PRT-EW
Optional Settings - Feature Table
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
FEATURE
Temperature Format
Switching Differential
Frost Mode
Frost Protection Temperature
Output Delay
Not in use on this model
RC2-W Address
Not in use on this model
Not in use on this model
Fail Safe
Up/Down Limit
Sensor Selection
Floor Limit
Optimum Start
Rate of Change
Program Mode
DESCRIPTION
00 =
o
C, 01 =
o
F (°C = Default)
01
o
- 03
o
C (01
o
C = Default)
00 = Enabled, 01 = Disabled (00 = Default)
07
o
- 17
o
C (12
o
C = Default)
00 - 15 Minutes (00 = Default)
01-32
00 = Disabled, 01 = Enabled (01 = Default)
00
o
-10
o
C (00
o
C = Default)
00 = Built in Air Sensor, 01 = Remote Air Sensor
20-45
o
C (28
o
C = Default)
00-03 Hours (00 = Default)
Minutes to raise by 1
o
C
00 = Weekday/Weekend
01 = 7 Day Programming
SETTING
Adjusting the Optional Settings
To adjust the optional settings, follow these steps.
•
Press and hold the Power button to turn the thermostat OFF ..............................
•
Press and hold the Clock key until the display appears as shown below ..........
•
Use the Clock key to cycle through the features ......................................................
•
Use the Up/Down keys to change the setting ....................................................
•
Press A to confirm settings .................................................................................................
•
Press the Power button once again to turn the thermostat back ON .................
Setting Value
Feature Number
Содержание PRT-EW
Страница 1: ...1 Model PRT EW Model PRT EW ...