FOR YOUR SAFETY READ BEFORE LIGHTING

A.  This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions 

exactly.

B.  BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS

+

Do not try to light any appliance.

+

Do not touch any electrical switch; do not use any phone in your building.

+

Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions.

+

If you cannot reach your gas supplier, call the fire department.

C.  Use only your hand to push in or turn the gas control handle, Never use tools. If the handle will not push in or turn 

by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or 
explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS
ROTARY CONTROL VALVE

1. STOP! Read the safety information previously listed above.
2. Turn the (MAIN) gas control handle clockwise          to the “OFF” position.
3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow

“B” in the safety information above on this label. If you don’t smell gas, go to the next step.

4. Locate pilot (Fig. 8) - located in the center behind the middle stainless steel burner underneath the middle log.
5.

Turn (MAIN) control handle counterclockwise          to the “PILOT” position (Fig. 7).

6. Place a lit match at the pilot burner, and simultaneously push in on the(MAIN) control knob. This should ignite the 

pilot. 

7. Once the pilot lights, continue to depress the(MAIN) control knob for one (1) minute.
8. After one minute, slowly release (MAIN) control knob and it will pop back out. Pilot should remain lit. If it goes out, 

repeat steps 1 thru 8.

+

If the handle does not pop out when released, stop and immediately call your service technician or gas supplier.

+

If the pilot will not stay lit after several tries, turn the (MAIN)  control knob to “OFF” and call your service 
technician or gas supplier.

9. Turn bottom (MAIN) control knob counterclockwise          to “ON”.

(NOTE:  Refer to page 10 of these instructions for operation of remote control or wall switch.)

TO TURN OFF GAS TO APPLIANCE

Turn control handle clockwise          to the “OFF” position. Do not force.

9

WARNING:

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 
personal injury or loss of life.

OFF

ON

PILOT

Fig. 7

Fig. 8

DUAL FLAME ADJUSTMENT

BOTTOM (MAIN) 
CONTROL KNOB

Содержание Gas Burner

Страница 1: ...dequate do not operate logs until draft is adequate If you smell fumes from the burner in the room when the damper is fully open it indicates that the fireplace draft is insufficient If the draft is i...

Страница 2: ...Fuel Gas Code ANSI Z223 1 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess o...

Страница 3: ...0 18 Log Set 49 2 45 5 41 7 37 7 34 3 31 2 24 Log Set 56 6 52 4 48 2 43 2 39 8 35 9 Table 1 Minimum Opening Square Inches Minimum Permanent Free Opening Square Inches for Factory Built Fireplaces Chim...

Страница 4: ...k of the fireplace as possible The fireplace will draft better with the burner unit toward the back of the fireplace Never place the burner assembly more toward the front in larger fireplaces 5 Remove...

Страница 5: ...charred face of the log facing the room Line up the two holes in the bottom of this log with the two 3 8 pegs and gently slide the log over the pegs until it rests on the grate Do not force 2 Remove t...

Страница 6: ...low Middle Log CHML 18 Glow Middle Log CHML 24 Back Log RAD 18 Back Log RAD 24 Back Log CHML 18 Back Log CHML 24 Left Middle Log RAD 18 Left Middle Log RAD 24 Left Middle Log CHML 18 Left Middle Log C...

Страница 7: ...ty information previously listed above 2 Turn gas control handle clockwise to the OFF position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas S...

Страница 8: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIG...

Страница 9: ...position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go...

Страница 10: ...and logs 2 It is recommended that a qualified electrician do the installation 3 The wall switch kit has a wall switch and cover and is designed to be installed in a standard wall switch box NOTE The w...

Страница 11: ...rol Valve Rotary 3 8 Black Street Elbow Screw 10 32 X 2 1 2 Square Nut 1 4 X 20 Valve Mounting Bracket Insulating Washer Burner Stainless Glow Burner Stainless Glow Valve Handle Bracket Insulating Mou...