background image

INSTALLATION INSTRUCTIONS FOR

INSTALLING A ROTARY VALVE UNIT

REMOTE CONTROL   

1.   Refer to pages 4 and 5 of these instructions for installation of the burner unit and logs.   
2. The remote control package has a hand held transmitter and a receiver with wires attached to it. 

NOTE:  The receiver requires 4 AA batteries (not included) and the transmitter requires one 9 volt 
transistor battery (not included). Do not install the batteries until all hookups are completed.

3. Remove the receiver and locate the two female terminals on the end of the wires. One of 

these terminals is smaller than the other one.   

4. Locate the two male terminals on the top right front of the valve.   
5. Plug the small female terminal from the receiver on the small male terminal of the valve.   
6. Plug the larger female terminal from the receiver on the larger male terminal of the valve.   
7. It is best to place the receiver in the fireplace as far away from the burner unit as possible 

to protect it from heat. Make sure the receiver eye is facing the room so it can receive the 
signal from the transmitter.   

8. Install batteries in the receiver by removing the back of the receiver where the wires go in.  
9. Install the battery in the hand held transmitter by removing the back of the unit. 

10. Follow LIGHTING INSTRUCTIONS on page 9 to light the pilot on your log set, and then follow item 6 under 

LIGHTING INSTRUCTIONS on page 9 to turn on your main control knob. CAUTION: Your log set may come on 
when you complete this step

11. You can now operate your log set with the hand-held transmitter. 
12. Push and hold the "ON" button of the transmitter to turn on the log set. 
13. Push and hold the "OFF" button of the transmitter to turn off the log set.

WALL SWITCH 

1. Refer to pages 4 and 5 of these instructions for installation of the burner unit and logs.  
2. It is recommended that a qualified electrician do the installation.   
3. The wall switch kit has a wall switch and cover and is designed to be installed in a 

standard wall switch box. NOTE: The wall switch requires 4 AA batteries (not included).
Do not install the batteries until all hookups are completed.

4. There must be two wires run from the switch box to the interior of the fireplace. If the wire 

furnished with the wall switch is not long enough, an electrician must run the correct length of 
wire.   

5. It is very important to connect the wires correctly between the wall switch and the valve. 

There is a small male terminal and a large male terminal located on the valve and there are two terminals on the 
back of the wall switch.  (NOTE: The terminals on the wall switch are labeled 1/4” and 3/16”.) Connect the wires 
from the small male terminal on the valve to the terminal marked 3/16” on the wall switch, and the large male 
terminal on the valve to the terminal marked 1/4” on the wall switch.  It is very important not 
to get the wires crossed when making this connection
.

6. After all connections are made, install the batteries and secure the switch and cover at the 

wall switch box.   

7. Follow LIGHTING INSTRUCTIONS on page 9 to light the pilot on your log set, and then follow item 6 under 

LIGHTING INSTRUCTIONS on page 9 to turn on your main control knob. CAUTION: Your log set may come on 
when you complete this step
.  

8. You can now operate your log set with the wall switch.   
9. Push and hold the "up arrow" on the wall switch to turn on the log set.

10. Push and hold the "down arrow" on the the wall switch to turn off the log set.

OPERATION OF THE REMOTE  CONTROL AND WALL SWITCH

The remote control and wall switch only operates when you are holding the  "ON" or "OFF" button down. You can turn the
log set up and down or turn the log set on and off. When you are depressing the "ON" and"OFF" button, watch the flame on
your log set and release the button when the log set is at the desired flame height.

10

Содержание Gas Burner

Страница 1: ...dequate do not operate logs until draft is adequate If you smell fumes from the burner in the room when the damper is fully open it indicates that the fireplace draft is insufficient If the draft is i...

Страница 2: ...Fuel Gas Code ANSI Z223 1 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess o...

Страница 3: ...0 18 Log Set 49 2 45 5 41 7 37 7 34 3 31 2 24 Log Set 56 6 52 4 48 2 43 2 39 8 35 9 Table 1 Minimum Opening Square Inches Minimum Permanent Free Opening Square Inches for Factory Built Fireplaces Chim...

Страница 4: ...k of the fireplace as possible The fireplace will draft better with the burner unit toward the back of the fireplace Never place the burner assembly more toward the front in larger fireplaces 5 Remove...

Страница 5: ...charred face of the log facing the room Line up the two holes in the bottom of this log with the two 3 8 pegs and gently slide the log over the pegs until it rests on the grate Do not force 2 Remove t...

Страница 6: ...low Middle Log CHML 18 Glow Middle Log CHML 24 Back Log RAD 18 Back Log RAD 24 Back Log CHML 18 Back Log CHML 24 Left Middle Log RAD 18 Left Middle Log RAD 24 Left Middle Log CHML 18 Left Middle Log C...

Страница 7: ...ty information previously listed above 2 Turn gas control handle clockwise to the OFF position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas S...

Страница 8: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIG...

Страница 9: ...position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go...

Страница 10: ...and logs 2 It is recommended that a qualified electrician do the installation 3 The wall switch kit has a wall switch and cover and is designed to be installed in a standard wall switch box NOTE The w...

Страница 11: ...rol Valve Rotary 3 8 Black Street Elbow Screw 10 32 X 2 1 2 Square Nut 1 4 X 20 Valve Mounting Bracket Insulating Washer Burner Stainless Glow Burner Stainless Glow Valve Handle Bracket Insulating Mou...