background image

LOG PLACEMENT PHOTOS

LOG PARTS LIST FOR CHML-18 & 24 and RAD-18 & 24

KEY

LETTER

A

B

C

D

E

PART NO.

Log # 381
Log # 363
Log # 382
Log # 364

Log # CF LOG 106

Log # CF LOG 107

Log # CF LOG 104

Log # CF LOG 105

Log # 380
Log # 200
Log # 380
Log # 200
Log # 260
Log # 260
Log # 287
Log # 287
Log # 275
Log # 275
Log # 179
Log # 179

PART NO.

Log # 19
Log # 285
Log # 313
Log # 19
Log # 337
Log # 19
Log # 19
Log # 264
Log # 280
Log # 280

DESCRIPTION

Front Log - RAD-18
Front Log - RAD-24
Front Log - CHML-18
Front Log - CHML-24
Glow Middle Log - RAD-18
Glow Middle Log - RAD-24
Glow Middle Log - CHML-18
Glow Middle Log - CHML-24
Back Log - RAD-18
Back Log - RAD-24
Back Log - CHML-18
Back Log - CHML-24
Left Middle Log - RAD-18
Left Middle Log - RAD-24
Left Middle Log - CHML-18
Left Middle Log - CHML-24
Right Middle Log - RAD-18
Right Middle Log - RAD-24
Right Middle Log - CHML-18
Right Middle Log - CHML-24

KEY

LETTER

F

G

H

DESCRIPTION

Left Top Log - RAD-18
Left Top Log - RAD-24
Left Top Log - CHML-18
Left Top Log - CHML-24
Right Top Log - RAD-18
Right Top Log - RAD-24
Right Top Log - CHML-18
Right Top Log - CHML-24
Middle Top Log - CHML-18
Middle Top Log - CHML-24

6

RAD-18

RAD-24

CHML-18

CHML-24

381

106

19

260

382

287

19

105

200

280

179

264

285

364

19

275

200

260

107

363

104

313

19

380

287

280

179

275

337

380

Содержание Gas Burner

Страница 1: ...dequate do not operate logs until draft is adequate If you smell fumes from the burner in the room when the damper is fully open it indicates that the fireplace draft is insufficient If the draft is i...

Страница 2: ...Fuel Gas Code ANSI Z223 1 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess o...

Страница 3: ...0 18 Log Set 49 2 45 5 41 7 37 7 34 3 31 2 24 Log Set 56 6 52 4 48 2 43 2 39 8 35 9 Table 1 Minimum Opening Square Inches Minimum Permanent Free Opening Square Inches for Factory Built Fireplaces Chim...

Страница 4: ...k of the fireplace as possible The fireplace will draft better with the burner unit toward the back of the fireplace Never place the burner assembly more toward the front in larger fireplaces 5 Remove...

Страница 5: ...charred face of the log facing the room Line up the two holes in the bottom of this log with the two 3 8 pegs and gently slide the log over the pegs until it rests on the grate Do not force 2 Remove t...

Страница 6: ...low Middle Log CHML 18 Glow Middle Log CHML 24 Back Log RAD 18 Back Log RAD 24 Back Log CHML 18 Back Log CHML 24 Left Middle Log RAD 18 Left Middle Log RAD 24 Left Middle Log CHML 18 Left Middle Log C...

Страница 7: ...ty information previously listed above 2 Turn gas control handle clockwise to the OFF position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas S...

Страница 8: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIG...

Страница 9: ...position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go...

Страница 10: ...and logs 2 It is recommended that a qualified electrician do the installation 3 The wall switch kit has a wall switch and cover and is designed to be installed in a standard wall switch box NOTE The w...

Страница 11: ...rol Valve Rotary 3 8 Black Street Elbow Screw 10 32 X 2 1 2 Square Nut 1 4 X 20 Valve Mounting Bracket Insulating Washer Burner Stainless Glow Burner Stainless Glow Valve Handle Bracket Insulating Mou...

Отзывы: