- 18 -
Service Call 0844 736 9138, Technical Help (Chargeable) Call 0906 802 0253
The external wiring must be earthed, with correct polarity and in
accordance with current standards.
The manufacturer declines any responsibility for damages to
persons or others caused by the incorrect installation of the
appliance earthing. This includes failure to comply with current
standards.
Electrical components have been tested to meet the equivalent
requirements of the BEAB.
• Do not use cable greater than 8 mm in diameter for the
electrical connections.
All system components must be of an approved type.
• Do not interrupt the mains supply with a time switch or
programmer.
The boiler is suitable for installation in bathroom zones 2 and 3.
10.2 Access to main board
1
2
2
3
Key
1 Control box
2 Control box securing screw
3 Mains cable
• Remove the control box securing screws (2) and pull the
control box (1) forward into the service position.
• Route the mains cable (3) through the grommet and connect
to the electrical plug on the controls board.
10.3 Main board
1
2
3
30mm
max
Key
1 Connector
2 Electrical wires
3 Insulation
When you connect the electrical wires to a connector on the
electronic board:
• Keep a distance of a maximum of 30 mm between connector
(1) and the start of the insulation (3).
• If using single core wires are used(2) ensure that the are
wrapped together in an insulating sheath.
• Fix the cables in the cable-clamp on the eBox.
10.4 Electrical wiring
Connection of the whole electrical system and any heating
system controls to the electrical supply must be through a
common isolator.
Isolation should preferably be by a double pole switched fused
spur box having a minimum contact separation of 3mm on each
pole. The fused spur box should be readily accessible and
preferably adjacent to the boiler. It should be identifi ed as to its
use.
A fused (3A) three pin plug and shuttered socket outlet may be
used instead of a fused spur box provided that it is not used in a
room containing a fi xed bath or shower.
• Connect the appliance's power cable to the 230 V single-
phase n earth.
• Connect the appliance in accordance with the live and
neutral connections.
230V permanent supply
a
All cables connected to the appliance should
be permanently fi xed to the wall. Ensure the
incoming electrical cable is clamped in the clamp
provided.
3
4
1
2
Key
1 230V permanent supply
2 Main board terminal block: = Mains earth, N = Mains
neutral
L = Mains live
3 Fuse
4 Double pole connector
• Connect mains supply as described.