Remove the fixing screws from the pump and
hydraulic block at the bottom of the boiler
(Figure 42).
Remove the pump assembly.
Remove the pump body from the hydraulic
assembly by releasing the clip.
Fit the replacement body in reverse order
ensuring that the pump washers are sound and
fitted correctly and the polarity of the electrical
connections are correct.
Open the isolating valves on the low and return
connections, refill, vent and re-pressurise the
system ensuring all joints are sound.
19.11 Low water pressure sensor
Drain the boiler’s hydraulic circuit as detailed in
(19.2).
Remove the pressure sensor by turning it in an
anticlockwise direction.
Fit the replacement sensor in reverse order of
removal ensuring all washers are fitted. Replace
damaged washers as necessary.
Open the isolating valves on the flow and return
connections, refill, vent and re-pressurise the
system ensuring all joints are sound.
19.12 Secondary Heat Exchanger
Drain the boiler’s hydraulic circuit as detailed in
(19.2)
Remove the two screws which connect the heat
exchanger to hydraulic circuit.
(Figure 44)
Remove the exchanger from the gap on the left hand
side.
Fit the new heat exchanger checking that the plate
numbers are the same and reassemble the boiler in
reverse order ensuring all washers are fitted or
replaced as required.
Open the isolating valves on the flow and return
connections, refill, vent and re-pressurise the
system ensuring all joints are sound.
Figure 45
Figure 43
Figure 44
Figure 42
Page 27
SECURING
SCREWS
SECURING
SCREW
ELECTRICAL
CONNECTIONS
LOW WATER
PRESSURE
SENSOR
SECURING SCREWS
THREE WAY
VALVE MOTOR
27
Содержание capriz 25
Страница 36: ...www heatline co uk 25 28 Condensing Wall Mounted Combination Boiler User Instructions 34...
Страница 40: ...Page 38 3005114697 38...